Intended to alert the user to the presence of uninsulated “dangerous voltage”  within the product’s 
enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. 

Intended to alert the user of the presence of important operating and maintenance (servicing) 
instructions in the literature accompanying the product. 

CAUTION:

 Risk of electrical shock — DO NOT OPEN! 

CAUTION:

 To reduce the risk of electric shock, do not remove cover. No user serviceable parts inside. 

Refer servicing to qualified service personnel. 

WARNING:

 To prevent electrical shock or fire hazard, do not expose this appliance to rain or moisture. 

Before using this appliance, read the operating guide for further warnings. 

Este símbolo tiene el propósito, de alertar al usuario de la presencia de “(voltaje) peligroso” sin 
aislamiento dentro de la caja del producto y que puede tener una magnitud suficiente como para 
constituir riesgo de descarga eléctrica. 

Este símbolo tiene el propósito de alertar al usario de la presencia de instruccones importantes sobre la 
operación y mantenimiento en la información que viene con el producto. 

PRECAUCION:

 Riesgo de descarga eléctrica ¡NO ABRIR! 

PRECAUCION:

 Para disminuír el riesgo de descarga eléctrica, no abra la cubierta. No hay piezas útiles 

dentro. Deje todo mantenimiento en manos del personal técnico cualificado. 

ADVERTENCIA:

 Para evitar descargas eléctricas o peligro de incendio, no deje expuesto a la lluvia o 

humedad este aparato Antes de usar este aparato, Iea más advertencias en la guía de operación. 

Ce symbole est utilisé dans ce manuel pour indiquer à l’utilisateur la présence d’une tension dangereuse 
pouvant être d’amplitude suffisante pour constituer un risque de choc électrique. 

Ce symbole est utilisé dans ce manuel pour indiquer à l’utilisateur qu’il ou qu’elle trouvera d’importantes 
instructions concernant l’utilisation et l’entretien de l’appareil dans le paragraphe signalé. 

ATTENTION:

 Risques de choc électrique — NE PAS OUVRIR!

ATTENTION:

 Afin de réduire le risque de choc électrique, ne pas enlever le couvercle. Il ne se trouve 

à l’intérieur aucune pièce pouvant être reparée par l’utilisateur. Confiez I’entretien et la réparation de 
l’appareil à un réparateur Peavey agréé.

AVERTISSEMENT

: Afin de prévenir les risques de décharge électrique ou de feu, n’exposez pas cet 

appareil à la pluie ou à l’humidité. Avant d’utiliser cet appareil, lisez attentivement les avertissements 
supplémentaires de ce manuel.

Dieses Symbol soll den Anwender vor unisolierten gefährlichen Spannungen innerhalb des Gehäuses 
warnen, die von Ausreichender Stärke sind, um einen elektrischen Schlag verursachen zu können. 

Dieses Symbol soll den Benutzer auf wichtige Instruktionen in der Bedienungsanleitung aufmerksam 
machen, die Handhabung und Wartung des Produkts betreffen. 

VORSICHT: 

Risiko — Elektrischer Schlag! Nicht öffnen! 

VORSICHT: 

Um das Risiko eines elektrischen Schlages zu vermeiden, nicht die Abdeckung enfernen. 

Es befinden sich keine Teile darin, die vom Anwender repariert werden könnten. Reparaturen nur von 
qualifiziertem Fachpersonal durchführen lassen.

ACHTUNG:

 Um einen elektrischen Schlag oder Feuergefahr zu vermeiden, sollte dieses Gerät nicht dem 

Regen oder Feuchtigkeit ausgesetzt werden. Vor Inbetriebnahme unbedingt die Bedienungsanleitung lesen. 

Summary of Contents for Q 1311

Page 1: ...Q Series Operation Manual For more information on other great Peavey products go to your local Peavey dealer or online at www peavey com ...

Page 2: ...mbole est utilisé dans ce manuel pour indiquer à l utilisateur la présence d une tension dangereuse pouvant être d amplitude suffisante pour constituer un risque de choc électrique Ce symbole est utilisé dans ce manuel pour indiquer à l utilisateur qu il ou qu elle trouvera d importantes instructions concernant l utilisation et l entretien de l appareil dans le paragraphe signalé ATTENTION Risques...

Page 3: ...d with the apparatus When a cart is used use caution when moving the cart apparatus combination to avoid injury from tip over 14 Unplug this apparatus during lightning storms or when unused for long periods of time 15 Refer all servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been s...

Page 4: ...accuracy Whether on stage in the studio or simply tweaking your home hi fi system the Q Series has an EQ for you FEATURES Q2151 Dual channel 15 bands per channel 2 3 octave filter sets 25 Hz to 16 kHz effective equalization range Constant Q filters Switchable 12 dB 6 dB of boost cut in each frequency band Output level LEDs 12 to 12 dB 24 dB per octave 40 Hz low cut filter with status LED XLR and 1...

Page 5: ...ot be attainable regardless of the equalizer used all system components must be of high quality and designed for the application No amount of equalization will correct poor acoustics poor microphone speaker arrangement or the response curve of a poor loudspeaker FEATURES AND CONTROLS 1 OUTPUT LEVEL LED METER This LED array indicates output level from 12 dB to 12 dB 2 GAIN This calibrated detented ...

Page 6: ...ent It is provided for your safety If the outlet used does not have a ground pin a suitable grounding adapter should be used and the third wire should be grounded properly To prevent the risk of shock or fire hazard always make sure that the equalizer and all associated equipment are properly grounded NOTE FOR UK USERS ONLY If the colors of the wires in the mains lead of this unit do not correspon...

Page 7: ...anced input when used with TRS connectors and two conductor shielded cables When used with mono 1 4 TS phone plugs the input is unbalanced 11 XLR INPUT These three pin female connectors provide balanced input when used with male XLR connectors 12 12 dB 6 dB SWITCH This switch changes the boost and cut range in each frequency band from 12 dB default to 6 dB for improved precision ...

Page 8: ...edance 200 Ohms Maximum Input Level 20 dBu Maximum Output Level 20 dBu Unbalanced 26 dBu Balanced Nominal Input Output Levels 0 dBu Input Headroom 20 dB Output Headroom 20 dB Unbalanced 26 dB Balanced Maximum Gain Boost Cut 12 dB Low Cut Filter 40 Hz 24 dB oct Power consumption Domestic 120 VAC 60 Hz 12 Watts Export 230 VAC 50 60 Hz 12 Watts Dimensions 1 73 44 mm H x 19 483 mm W x 7 375 187 mm D W...

Page 9: ...9 Q Series BLOCK DIAGRAM ...

Page 10: ...ill pay the return shipping charges How To Get Warranty Service 1 Take the defective item and your sales receipt or other proof of date of purchase to your Authorized Peavey Dealer or Authorized Peavey Service Center OR 2 Ship the defective item prepaid to Peavey Electronics Corporation International Service Center 412 Highway 11 80 East Meridian MS 39301 or Peavey Canada Ltd 95 Shields Court Mark...

Page 11: ...Features and specifications subject to change without notice Peavey Electronics Corporation 711 A Street Meridian MS 39301 601 483 5365 FAX 601 486 1278 www peavey com 2002 Printed in the U S A 8 02 ...

Reviews: