Peavey PVXp 15 DSP Operating Manual Download Page 10

Rotate the “Push-to-Select” knob to choose the amount of boost or cut in 1dB increments from +6 dB down to - 

6dB. these tone changes occur on top of an existing factory EQ preset.

To exit the treble menu, press the “Push-to-Select”, the cursor will then shift back to the “function” side of the 

LCD.

Bass: 

The bass control can be used to boost or cut the low frequency response of the speaker up to +/-6dB. It can 

be used to add bass to a “thin” source or to remove boomy bass from the speakers.

Rotate the “Push-to-Select” knob to choose the amount of boost or cut in 1dB increments from +6 dB down to - 

6dB. these tone changes occur on top of an existing factory EQ preset.

To exit the treble menu, press the “Push-to-Select”, the cursor will then shift back to the “function” side of the 

LCD.

P. Save (Power Save):

 The power save settings are “on” and “off”. In the “off” position, the LCD is illuminated 

at all times. In the “on” position, the LCD is illuminated until the user stops using the controls. The LCD back-

light will turn off about 1 minute after the last on screen change. To turn the backlight back on, simply rotate the 

“Push-to-Select” knob.

Bright: 

Various conditions (like bright sun) or even the position of the speaker can sometimes make the LCD 

difficult to see or read. Two adjustments have been included to improve the visibility of the LCD. The first is a 

brightness adjustment. It varies the brightness of the illuminated characters on the screen. Turning the adjust-

ment clockwise makes it brighter, while turning it counter-clockwise makes the characters dimmer.

 

Contr (Contrast):

 The second adjustment is the contrast. The contrast adjustment can be used to improve the 

viewing angle of the LCD. This may need to be adjusted if the speaker is overhead (like on a pole) or on the floor. 

You may have to try some experimenting with this control to improve the visibility of the LCD.

System Reset:

 Selecting the “System Reset” returns the DSP section to the factory settings. There is a confirma-

tion screen to prevent accidental changes.

System Info:

 Selecting the “System Info” displays the copyright information and firmware version of the operat-

ing system. Push the “push-to-select” knob again to return to the function screen.

TROUBLESHOOTING

No Output at All

First, make sure the unit has AC power and is turned ON.  Make sure the  LCD on the power amp module is 

illuminated. 

If not, make certain the ON/OFF switch (1) is in the ON position and check the IEC power cord connection (3) 

by ensuring it is fully engaged and seated. Make certain the AC line cord is plugged into a working AC outlet.

Finally, check the fuse (2). (See the Rear Panel: FUSE section, for safety instructions.)

Once assured your unit is getting AC power, check that the PVXp™ 15 DSP is getting a signal. Temporarily 

disconnect the cable running to its inputs and connect it to some other device capable of reproducing the signal 

(i.e., a power amp and speaker). If this produces a signal, make sure that all Level controls being used have been 

turned up to a satisfactory level (one-third to halfway).

Summary of Contents for PVXp 15 DSP

Page 1: ...www peavey com PVXp 15 DSP Powered Speaker System Operating Manual...

Page 2: ...the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This...

Page 3: ...r professional grade components Fan cooled for maximum reliability Patented Quadratic Throat Waveguide technology 100 by 50 degree coverage Asymmetrical horn aims the sound down 10 degrees at the audi...

Page 4: ...lay The PVXp 15 DSP speaker system power amplifiers providing the bi amplification are low distortion ultra reli able fan cooled units providing a total of 830 peak available dynamic power for the sys...

Page 5: ...ips Then once the fresh fuse has been put in place re insert the fuse tray into the IEC connector assembly and make sure it is fully seated and flush with the outside of the IEC connector assembly It...

Page 6: ...connecting a cd or MP3 players Gnd LIFT switch 5 Allows the shield to be disconnected from the chassis ground to alleviate hum from ground loops Level 6 Controls the gain or output level of the input...

Page 7: ...o the system is likely if this occurs DO NOT connect the inputs of the PVXp 15 DSP to the output of a power amplifier The inputs are meant to be driven from a line level strength signal DO NOT remove...

Page 8: ...system from being blown over Connecting a Signal to the PVXp 15 DSP There are a variety of ways to input a signal to the PVXp 15 DSP The input 4 provides either a balanced mic or line level input allo...

Page 9: ...o reach full desired output With this approach it is necessary to verify the mixer output is not clipping Disconnecting AC Power to the PVXp 15 DSP We recommend that the Power switch 1 be used to turn...

Page 10: ...s on the screen Turning the adjust ment clockwise makes it brighter while turning it counter clockwise makes the characters dimmer Contr Contrast The second adjustment is the contrast The contrast adj...

Page 11: ...ed or broken off as this is a potential safety hazard Distorted or Fuzzy Sound First ensure the mixer signal source is not clipping or being overdriven Make sure the Level 6 control on the PVXp 15 DSP...

Page 12: ...f 1M and driven to full output capacity The system shall utilize a Peavey Pro 15 15 heavy duty woofer and a Peavey RX 14 1 4 titanium diaphragm dynamic compression driver The nominal radiation pattern...

Page 13: ...e manual update notices This system should be suspended with certi fied rigging hardware by an authorized rigging professional and in compliance with local state or provincial and federal or national...

Page 14: ...that does not penetrate the cabinet beyond the cabinet surface more than 3 4 approx 20 mm When using a Peavey Versamount 70 mounting bracket and lock washer the length of the bolt should not exceed 1...

Page 15: ...ey filter Input Connections One combo female XLR and 1 4 phone jack providing balanced line level operation from the 1 4 jack section and high output dynamic microphone operation from the XLR section...

Page 16: ...al Line 2 2 k ohms balanced 1 4 10 k ohms unbalanced 1 4 Mic 2 2 k ohms balanced XLR No phantom power available Input Sensitivity for Full Output Level full CW 0 48V RMS in the Line position 0 01V RMS...

Page 17: ...8 205 mm 3 35 85 mm 6 153 mm 5 127 mm 2 76 70 mm 2 76 70 mm 10 24 260 mm 17 430 mm 9 45 240 mm 18 9 480 mm 5 127 mm 28 710 mm 14 357 mm 9 45 240 mm 5 127mm 6 26 159 mm 2 76 70 mm 2 76 70 mm 8 205 mm 3...

Page 18: ...d only to equipment manufactured after 13 August 2005 www peavey com Warranty registration and information for U S customers available online at www peavey com warranty or use the QR tag below Feature...