Intended to alert the user to the presence of uninsulated “dangerous voltage”  within the product’s 
enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. 

Intended to alert the user of the presence of important operating and maintenance (servicing) 
instructions in the literature accompanying the product. 

CAUTION:

 Risk of electrical shock — DO NOT OPEN! 

CAUTION:

 To reduce the risk of electric shock, do not remove cover. No user serviceable parts inside. 

Refer servicing to qualified service personnel. 

WARNING: To prevent electrical shock or fire hazard, this apparatus should not be exposed to rain or 
moisture‚ and objects filled with liquids‚ such as vases‚ should not be placed on this apparatus. Before 
using this apparatus‚ read the operating guide for further warnings.

 

Este símbolo tiene el propósito, de alertar al usuario de la presencia de “(voltaje) peligroso” sin 
aislamiento dentro de la caja del producto y que puede tener una magnitud suficiente como para 
constituir riesgo de descarga eléctrica. 

Este símbolo tiene el propósito de alertar al usario de la presencia de instruccones importantes sobre la 
operación y mantenimiento en la información que viene con el producto. 

PRECAUCION:

 Riesgo de descarga eléctrica ¡NO ABRIR! 

PRECAUCION:

 Para disminuír el riesgo de descarga eléctrica, no abra la cubierta. No hay piezas útiles 

dentro. Deje todo mantenimiento en manos del personal técnico cualificado. 

ADVERTENCIA: Para prevenir choque electrico o riesgo de incendios, este aparato no se debe exponer a 
la lluvia o a la humedad. Los objetos llenos de liquidos, como los floreros, no se deben colocar encima 
de este aparato. Antes de usar este aparato, lea la guia de funcionamiento para otras advertencias. 

 

Ce symbole est utilisé dans ce manuel pour indiquer à l’utilisateur la présence d’une tension dangereuse 
pouvant être d’amplitude suffisante pour constituer un risque de choc électrique. 

Ce symbole est utilisé dans ce manuel pour indiquer à l’utilisateur qu’il ou qu’elle trouvera d’importantes 
instructions concernant l’utilisation et l’entretien de l’appareil dans le paragraphe signalé. 

ATTENTION:

 Risques de choc électrique — NE PAS OUVRIR!

ATTENTION:

 Afin de réduire le risque de choc électrique, ne pas enlever le couvercle. Il ne se trouve 

à l’intérieur aucune pièce pouvant être reparée par l’utilisateur. Confiez I’entretien et la réparation de 
l’appareil à un réparateur Peavey agréé.

AVIS: Dans le but de reduire les risques d’incendie ou de decharge electrique, cet appareil ne doit 
pas etre expose a la pluie ou a l’humidite et aucun objet rempli de liquide, tel qu’un vase, ne doit 
etre pose sur celui-ci. Avant d’utiliser de cet appareil, lisez attentivement le guide fonctionnant pour 
avertissements supplémentaires.

Dieses Symbol soll den Anwender vor unisolierten gefährlichen Spannungen innerhalb des Gehäuses 
warnen, die von Ausreichender Stärke sind, um einen elektrischen Schlag verursachen zu können. 

Dieses Symbol soll den Benutzer auf wichtige Instruktionen in der Bedienungsanleitung aufmerksam 
machen, die Handhabung und Wartung des Produkts betreffen. 

VORSICHT: 

Risiko — Elektrischer Schlag! Nicht öffnen! 

VORSICHT: 

Um das Risiko eines elektrischen Schlages zu vermeiden, nicht die Abdeckung enfernen. 

Es befinden sich keine Teile darin, die vom Anwender repariert werden könnten. Reparaturen nur von 
qualifiziertem Fachpersonal durchführen lassen.

WARNUNG: Um elektrischen Schlag oder Brandgefahr zu verhindern, sollte dieser Apparat nicht 
Regen oder Feuchtigkeit ausgesetzt werden und Gegenstände mit Flüssigkeiten gefuellt, wie Vasen, 
nicht auf diesen Apparat gesetzt werden. Bevor dieser Apparat verwendet wird, lesen Sie bitte den 
Funktionsführer für weitere Warnungen.

Summary of Contents for PV I 8B+

Page 1: ...www peavey com PV i 8B 350 Watt 8 Channel Mixer Amplifier Operating Manual ...

Page 2: ...lisé dans ce manuel pour indiquer à l utilisateur la présence d une tension dangereuse pouvant être d amplitude suffisante pour constituer un risque de choc électrique Ce symbole est utilisé dans ce manuel pour indiquer à l utilisateur qu il ou qu elle trouvera d importantes instructions concernant l utilisation et l entretien de l appareil dans le paragraphe signalé ATTENTION Risques de choc élec...

Page 3: ...ect only to a power supply of the type marked on the unit adjacent to the power supply cord 16 If this product is to be mounted in an equipment rack rear support should be provided 17 Note for UK only If the colors of the wires in the mains lead of this unit do not correspond with the terminals in your plug proceed as follows a The wire that is colored green and yellow must be connected to the ter...

Page 4: ...rocución y Toma a Tierra Conecte el aparato sólo a una fuente de alimentación del tipo marcado al lado del cable de alimentación 16 Si este producto va a ser enracado con más equipo use algún tipo de apoyo trasero 17 Nota para el Reino Unido solamente Si los colores de los cables en el enchufe principal de esta unidad no corresponden con los terminales en su enchufe proceda de la siguiente manera ...

Page 5: ...ease read this guide carefully to ensure your personal safety as well as the safety of your equipment ENGLISH Features 350 watts into 4 ohm 2 x 8 ohm speakers 8 Balanced microphone and line inputs Tape CD inputs Reverb level control on each channel Line Out for connection to external amplifiers Monitor output for connection to external amplifiers Return input for connection of external effects pro...

Page 6: ... Front Panel Rear Panel ...

Page 7: ... 6 MID TONE CONTROL This is used to adjust the overall tone of the individual inputs Since it is a cut or boost control 12 db it will add or diminish presence frequencies in the sound beginning at 2 5 kHz 7 LOW TONE CONTROL This is used to adjust the overall tone of the individual inputs Since it is a cut or boost control 15 dB it will add or diminish bass frequencies in the sound beginning at 100...

Page 8: ... cassette deck CD player or other line level source 27 TAPE OUT L R These RCA output jacks are primarily intended for connecting a tape deck MP3 player or other device for the purpose of recording from the mixer Both channels are summed into mono for compatibility The signals are taken pre master section meaning that they are without reverb or the master tone section and do not include the Tape In...

Page 9: ...perate below minimum rated impedance 3 MONITOR OUTPUT Two conductor 1 4 speaker output rated at 4 ohms impedance Also this serves as one of the main speaker outputs when in MAIN MAIN mode Do not operate below minimum rated impedance 4 POWER CONNECTOR This is a standard IEC cable connector for use with standard voltages from AC wall outlets Its safety ground pin is connected to the chassis and shou...

Page 10: ...2 500 Hz or 2 5Khz Treble Control 8 000 Hz or 8kHz Master Graphic Equalization 63 Hz 12 dB 160 Hz 12 dB 400 Hz 12 dB 2 5 kHz 12 dB 6 3 kHz 12 dB 16 kHz 12 dB Protection Circuit Power on Mute delay time 2 seconds Power Consumption 450 watts Dimensions HxWxD 11 25 in x 19 in x 11 25 in 28 6 cm x 48 3 cm x 28 6 cm Weight 39 lbs 17 7 kg PV i8B SPECIFICATIONS Logo referenced in Directive 2002 96 EC Ann...

Page 11: ...11 Notes ...

Page 12: ...Features and specifications subject to change without notice Peavey Electronics Corporation 5022 Hartley Peavey Drive Meridian MS 39305 601 483 5365 FAX 601 486 1278 www peavey com EX 000050 2006 ...

Reviews: