background image

4

BACK PANEL FEATURES:

FUSE (6)

WARNING: THE FUSE SHOULD ONLY BE REPLACED WHEN THE POWER CORD HAS
BEEN DISCONNECTED FROM ITS POWER SOURCE.

CAUTION:  USING A FUSE LARGER THAN THE RECOMMENDED SIZE COULD
RESULT IN PERMANENT DAMAGE TO THE AMPLIFIER.

The fuse is located within the cap of the fuseholder. If the fuse should fail, IT MUST BE REPLACED
WITH THE SAME TYPE AND VALUE IN ORDER TO AVOID DAMAGE TO THE EQUIPMENT
AND TO PREVENT VOIDING THE WARRANTY. If the unit repeatedly blows fuses, it should be
taken to a qualified service center for repair.

INPUT SENSITIVITY CONTROLS (7)

Maximum input gain (minimum sensitivity rating) is achieved at full clockwise setting. This setting yields maximum
mixer/system headroom. A setting of less than one full clockwise turn will yield lower system noise at the expense of
mixer/system headroom.

AMPLIFIER INPUTS (8)

The terminal strip is configured to allow balanced or unbalanced input signals. When using an unbalanced input signal,
a jumper wire should be placed between the  ( - ) and GND terminals.

LINE OUTPUT (9)

This terminal strip is provided to drive the input of other amplifiers. It is a balanced 600 ohm line output.

MATRIX (10)

This jack is to be used with Peavey’s MediaMatrix system. This allows for remote status and control of the amplifier or
several amplifiers.

DC POWER CONNECTOR (11)

This terminal strip should be connected to a battery backup DC power supply with a voltage of approximately
24 V DC. It is important to correctly wire this so that the positive terminal is connected to the positive side of the
battery. An improper connection can result in damage to the battery and/or the amplifier.

AMPLIFIER OUTPUTS (12)

Fully isolated terminal strip is provided for 25 volt and 70 volt line outputs. When using the 25 volt line output the load
impedance should be 4 ohm and when using the 70 volt line output an impedance of approximately 33 ohms is recom-
mended.

Rear Panel:

Summary of Contents for IDC 150T II

Page 1: ...1 Cover for IDC 150TII ...

Page 2: ...ymbole est utilisé pur indiquer à l utilisateur la présence à l intérieur de ce produit de tension non isolée dangereuse pouvant être d intensité suffisante pour constituer un risque de choc électrique Ce symbole est utilisé pour indiquer à l utilisateur qu il ou qu elle trouvera d importantes instructions sur l utilisation et l entretien service de l appareil dans la littérature accompagnant le p...

Page 3: ...is also provided to help eliminate distortion due to clipping A balanced 600 ohm line out is available to provide signal to additional amplifiers FRONT PANEL FEATURES SPS LED INDICATOR 1 When the SPS compression is active this indicator illuminates to show that the amplifier is being overdriven to the point that the signal runs out of headroom POWER LED INDICATORS MAINS 2 24 V DC 3 Mains Illuminat...

Page 4: ...al strip is configured to allow balanced or unbalanced input signals When using an unbalanced input signal a jumper wire should be placed between the and GND terminals LINE OUTPUT 9 This terminal strip is provided to drive the input of other amplifiers It is a balanced 600 ohm line output MATRIX 10 This jack is to be used with Peavey s MediaMatrix system This allows for remote status and control o...

Page 5: ... Peavey is notified Peavey will repair or replace it at no charge Note Batteries and patch cords not covered Original purchaser means the customer for whom the product is originally installed Damage resulting from improper installation interconnection of a unit or system of another manufacturer accident or unreasonable use neglect or any other cause not arising from defects in material and workman...

Page 6: ...measurement AC powered 100 W RMS 70 volt and 25 volt lines 20 Hz to 15 kHz below 0 15 THD Signal To Noise Ratio unweighted 20 Hz to 22 kHz FCW attenuator setting S N below 103 db Slew Rate typical value 10 V µs Damping Factor typical value 25 volt line 1 kHz 50 70 volt line 1 kHz 100 Input Impedance FCW attenuator setting Balanced 10 k ohms Unbalanced 10 k ohms Input Sensitivity FCW attenuator set...

Page 7: ...7 ...

Page 8: ... not fall and liquids are not spilled into the unit through the ventilation holes or any other openings 15 This unit should be checked by a qualified service technician if a The power supply cord or plug has been damaged b Anything has fallen or been spilled into the unit c The unit does not operate correctly d The unit has been dropped or the enclosure damaged 16 The user should not attempt to se...

Reviews: