background image

10

Classic

®

 50

Guitar Amplifier

SPECIFICATIONS

POWER AMPLIFIER SECTION

Four 6BQ5/EL84’s with 12AX7 driver

Rated Power & Load:

 

50 W RMS into 16 or 8 ohms

Power @ Clipping (Typically):

  

(5% THD, 1 kHz, 120 V AC line)
50 W RMS into 16 or 8 ohms
(Bias must be reduced to measure)

Frequency Response:

 

+0, -2 dB, 50 Hz to 15 kHz, @ 40 W RMS into 16 ohms

Hum & Noise:

No greater than 80 dB below rated power

Power Consumption:

  

200 watts, 50/60 Hz, 120 VAC (Domestic)

PREAMP SECTION

Two 12AX7’s

The following specs are measured @ 1 kHz with the controls 
preset as follows:

Pre & Post (lead) @ 0
Reverb Level @ 0
Bass & Treble EQ @ 12
Middle EQ @ 0
Master Volume @ 12
Presence @ 6

Nominal level is with Input Gain @ 6.
Minimum level is with Input Gain @ 12. 

 

Preamp Normal Input:

   

 

Impedance: Very high Z, 470 K ohms

Lead Channel (Post Gain @ 10):

 

 

Nominal Input Level:

 

-40 dBV, 10 mV RMS

 

Minimum Input Level:

 

-70 dBV, 0.3 mV RMS

PREAMP SECTION, continued
Normal Channel:

 

 

Nominal Input Level:

 

-17 dBV, 140 mV RMS

 

Minimum Input Level:

 

-28 dBV, 40 mV RMS

 

Maximum Input Level:

 

0 dBV, 1.0 V RMS

Preamp Bright Input:

 

Impedance: Very high Z, 470 K ohms  
 

         +12 dB boost @ 2 kHz

Equalization:

 

(Lead and Normal Channels)

 

Custom bass, middle, and treble passive-type EQ

Effects Send:

 

 

Load Impedance:  1 K ohm or greater

 

Nominal Output Level:  -6 dBV, 0.5 V RMS

Effects Return:

 

 

Impedance:  High Z, 2 M ohms

 

Designed Input Level:  -6 dBV, 0.5 V RMS

(Switching jack provides Effects Send to Effects Return 
connection when not used.)

External Footswitch Function:

 

Reverb Defeat (when reverb control is raised)
Normal/Lead Channel Select (when Lead activated)

Summary of Contents for Classic 50 212

Page 1: ...www peavey com Classic 50 212 410 GUITAR AMPLIFIER Operating Manual...

Page 2: ...est utilis dans ce manuel pour indiquer l utilisateur la pr sence d une tension dangereuse pouvant tre d amplitude suffisante pour constituer un risque de choc lectrique Ce symbole est utilis dans ce...

Page 3: ...ect only to a power supply of the type marked on the unit adjacent to the power supply cord 16 If this product is to be mounted in an equipment rack rear support should be provided 17 Note for UK only...

Page 4: ...eruntergefallen ist 15 Der Erdungsstift darf nie entfernt werden Auf Wunsch senden wir Ihnen gerne unsere kostenlose Brosch re Shock Hazard and Grounding Gefahr durch elektrischen Schlag und Erdung zu...

Page 5: ...etre utilises 17 Note pour les Royaumes Unis Si les couleurs de connecteurs du cable d alimentation ne correspond pas au guide de la prise secteur proc dez comme suit a Le connecteur vert et jaune do...

Page 6: ...ctrocuci n y Toma a Tierra Conecte el aparato s lo a una fuente de alimentaci n del tipo marcado al lado del cable de alimentaci n 16 Si este producto va a ser enracado con m s equipo use alg n tipo d...

Page 7: ...pplied to the amp PRESENCE 5 An active tone control that boosts the extreme high frequencies by up to 6 dB MASTER VOLUME 6 Controls the overall volume level of the system TREBLE MIDDLE AND BASS EQ 7 P...

Page 8: ...el of the Lead channel NORMAL GAIN 11 Controls the volume level of the Normal channel BRIGHT INPUT 12 Input for instrument level signals This input produces enhanced high frequency response treble sim...

Page 9: ...the ground switch to either positive or negative or or until the noise is minimized NOTE Should the noise problem continue consult your Authorized Peavey Dealer the Peavey Factory or a qualified servi...

Page 10: ...nimum level is with Input Gain 12 Preamp Normal Input Impedance Very high Z 470 K ohms Lead Channel Post Gain 10 Nominal Input Level 40 dBV 10 mV RMS Minimum Input Level 70 dBV 0 3 mV RMS PREAMP SECTI...

Page 11: ...om versorgt wird PRESENCE 5 Aktiver Klangregler mit dem die extrem hohen Frequenzen um bis zu 6 dB angehoben werden MASTER VOLUME 6 Regler f r die Gesamtlautst rke des Systems TREBLE MIDDLE UND BASS E...

Page 12: ...d Kanals NORMAL GAIN 11 Regelt den Lautst rkepegel des Normal Kanals BRIGHT EINGANG 12 Eingang f r Signale mit Instrumentenpegel Dieser Eingang erh ht die Wiedergabe der hohen Frequenzen Treble hnlich...

Page 13: ...leiser wird HINWEIS Sollte das Ger uschproblem andauern wenden Sie sich bitte an Ihren autorisierten Peavey H ndler das Peavey Werk oder einen qualifizierten Kundendiensttechniker DER ERDUNGSSCHALTER...

Page 14: ...ngangs Gain auf 6 Mindestpegel bei Eingangs Gain auf 12 Vorverst rkereingang Normal Impedanz Sehr hochohmig 470 kOhm Lead Kanal Post Gain auf 10 Nenneingangspegel 40 dBV 10 mV RMS Mindesteingangspegel...

Page 15: ...mentation CA Presence 5 R glage de tonalit actif qui renforce les fr quences aigu s 6 dB Principal volume 6 Contr le le niveau de volume g n ral du syst me Egalisation aigu s moyennes graves 7 R glage...

Page 16: ...l Lead Gain canal normal 11 Contr le le niveau de volume du canal Normal Entr e Bright 12 Entr e pour signaux de niveau instrument Cette entr e produit une r ponse accentu e des fr quences aigu s simi...

Page 17: ...n du bruit NOTE Dans le cas ou le probl me de bruit perdure veuillez contacter votre revendeur ou un technicien agr e Peavey LE SELECTEUR DE TERRE N EST PAS FONCTIONNEL SUR LES MODELES 220 240 VOLT So...

Page 18: ...n gain d entr e 12 Entr e normale pr amplificateur Impedance Tr s Haute 470 K ohms Canal Lead Post Gain 12 Niveau d entr e Nominal 40 dBV 10 mV RMS Niveau d entr e Minimum 70 dBV 0 3 mV RMS SECTION PR...

Page 19: ...lumina cuando el amplificador recibe corriente alterna Presencia 5 Control de tono activo que aumenta en 6 dB las frecuencias de los extremos agudos Volumen maestro 6 Controla el nivel global de volum...

Page 20: ...ta Ganancia normal 11 Controla el nivel de volumen del canal Normal Entrada de brillo 12 Esta entrada es para las se ales a nivel de instrumentos Esta entrada produce una respuesta de frecuencias agud...

Page 21: ...de tierra en positivo o negativo or o hasta que el ruido haya disminu do NOTA Si persistiera el problema del ruido consulte a su Distribuidor Autorizado de Peavey a la F brica Peavey o a un Servicio T...

Page 22: ...m nimo es con la ganancia de entrada a 12 Entrada Normal de Previo Impedancia Z Muy Alta 470 K ohmios Canal Solista Post Gain a 10 Nivel de Entrada Nominal 40 dBV 10 mV RMS Nivel de Entrada M nimo 70...

Page 23: ...eceipt or other proof of date of purchase to your Authorized Peavey Dealer or Authorized Peavey Service Center OR 2 Ship the defective item prepaid to Peavey Electronics Corporation International Serv...

Page 24: ...Features and specifications subject to change without notice Peavey Electronics Corporation 5022 Hartley Peavey Drive Meridian MS 39305 601 483 5365 FAX 601 486 1278 www peavey com 2005 80305327...