Schematic diagram of main unit
System working mode setting
- 2 -
Meeting host and computer connection
●
Net weight of main engine: 11.8kg
Dimensions: 485mm (including handle) 100mm (2U, including chassis
pad) 355mm (W H D);Can be placed horizontally on the table or mounted
in a 19-inch standard cabinet.
The system can be connected to automatic tracking video system and
voting system.
●
×
×
× ×
●
When the number of speaking devices in the meeting reaches 70, a master
control machine cannot meet its needs. At this time, it is necessary to extend
the host machine to provide power.
Power consumption: 450W.
Has four sets of 8P-DIN sockets for system multiplexing or connecting to
other extension hosts.
This machine adopts 220v-230v ~ 50hz-60hz ac power supply.
Dimensions: 485mm (including handle) 100mm (2U, including chassis
pad) 355mm (W H D);Can be placed horizontally on the table or mounted
in a 19-inch standard cabinet.
●
●
●
●
×
×
× ×
1.POWER switch (press 1 to open the POWER supply, and the POWER
indicator will be on.Press 0 to turn off the power and turn off the light)
2, MODE button, can choose: free MODE, rotation MODE (1 to 9), limit
MODE (1 to 9), panel control MODE, computer control MODE.
3. NUMBER of speakers (1 to 9)
4. SAVE
5. LCD display
6. Wired microphone volume potentiometer (MIC)
7. AUX volume potentiometer (AUX)
8. MONITOR volume potentiometer
9. Total output volume potentiometer (MASTER)
10. UNIT volume potentiometer (unit. VOL)
11. Computer interface (rs-232)
12. TREBLE gain knob of the system
1.The network controller is used to connect to the DATA interface of the main
control machine, the USB port of the controller is connected to the USB
interface of the computer, and the NET terminal of the controller is connected
to the DATA interface of the main control machine through the network cable
(over 5 types of network cable, the longest is 1000 meters).(the drive is
CH341SER, and the network controller and network cable are factory standard)
2.Connect the RS232 (PC) interface with the serial port line (9 pins, one male,
one bus line).
3.Connect RS232 (PC) interface with USB to RS232 serial port line, the serial
port line with crystal of CH340 must be used.(driven by CH341SER)
Note: when connecting the computer running software, the conference system
line must be connected to ID001 non-voting unit to run the software normally.
Press the MODE key of the host, and the corresponding text will be displayed
on the LCD screen. The modes are: free MODE, limit MODE, rotation MODE,
computer MODE and panel MODE.
After selecting the mode, press the SAVE button to SAVE it. The submode
(optional) has chairman's special purpose, chairman's prompt tone and
automatic shutdown.
After selecting the submode, press the SAVE key to SAVE it.
Host control mode (panel mode) :
A. Press MODE key to select until the LCD displays "panel MODE";
B. Press SAVE;
C. Press MODE again to select: free MODE, alternate MODE, restricted MODE,
one of them.
D. Press SAVE;If rotation or restriction mode is selected in (c), perform the
following steps:
E. When selecting the above two modes, "NUMBER of speakers: people" appears
in the LCD. At this time, press the NUMBER key to set the NUMBER, (1 to 9).
F. Press SAVE.If any of the patterns in (c) is selected, the following sub-pattern
steps can be continued:
G. Press MODE key to select one of them until LCD displays chairman's special
purpose, chairman's prompt tone and automatic shutdown.
H. Press the NUMBER key to select the appropriate submode to turn on () or off ().
I. Press SAVE.
Computer control mode (computer mode) :
A. Press MODE key until LCD display: "computer MODE".
B. Press SAVE.
Speech time limit setting
A. Press MODE key until LCD display: "speech time limit".
B. Press SAVE.
C. Press MODE key again to decrease the speaking time;
- 7 -
Summary of Contents for CM-5800
Page 2: ......