8. VOLTAGE CHANGE PROCEDURE
9. PEARL MOTOR DATA
10. MOTOR FACTORY PRE-WIRING
PEARL Motors for our THOR Pumps are factory pre-wired at 230 V.
MOTOR PART #
HP
VOLTS
PHASE
SERVICE FACTOR
Pump MAX. LOAD
AMPS
THOR 10
1
115 V / 230 V
1
1.75
16.60 / 8.30
THOR 15
1.5
115 V / 230V
1
1.60
21.00 / 10.50
THOR 20
2
230
1
1.40
11.8
Unscrew and
remove the cover.
Remove the
Voltage plug.
Install the Voltage
Plug aligning the
arrow with the
voltage needed.
Choose connection
for 115 V.
Reinstall the cover
back.
Choose connection
for 230 V.
1
4
5
6
2
3