background image

PROBLEM

POSSIBLE CAUSE

SOLUTION

Insufficient pressure

Incorrect pump type

Select suitable pump

The inlet pipeline is too long or with too 

many bends, pipe diameter is not selected 

as required.

Apply the pipe with the stipulated diameter, and 

make the inlet pipe short.

Inlet pipeline, filter screen or pump chamber 

is blocked by foreign materials

Clean pipeline, foot valve or pump chamber, 

clear sundries

Motor works intermittently  

or the stator winding is 

burned out

The impeller is jammed or overload operation 

for a long time

Clear sundries in the pump chamber; operate 

the pump under the rated flow as much as 

possible.

Incorrect grounding, broken cable or the 

electric pump is hit by lightning.

Seek for the reason, and replace winding coils.

... troubleshooting cont.

3000 W. 16 Ave. Miami, FL 33012

Tel: (954) 4749090 | Fax: (954) 8890413

[email protected] | www.pearlwatersystems.com

Reviews: