background image

Self priming jet cast iron pumps

JCP-JSP

INSTALLATION AND OPERATING INSTRUCTIONS

Before installation, you should carefully read 

this manual, and pay attention to safety 

cautions and instructions in this manual.  

Our factory is neither responsible for nor is 

reliable for paying compensation for personal 

injury, pump damage and other property 

losses caused by violation of safety cautions.

1.  APPLICATIONS

1) It is applicable to household water supply, equipment sup-

port, well water lifting, pipeline pressurization, garden watering, 

vegetable greenhouse watering, fish farming and poultry 

raising, etc.

2) Transfer clean water and other non-corrosive liquids with 

low viscosity; do not transport inflammable, explosive, gasified 

liquids and liquids containing solid particles or fibers. The PH 

value should be within 6.5-8.5.

Remark: 

 

This series of pump could be transformed into automatic water 

pump, which is realized through external automatic plant that 

is composed of pressure switch, pressure tank, etc. Function 

features of the automatic pump are as follows: when the power 

is on, turn on the water tap and the pump will start working 

automatically; when the water tap is turned off, the pump will 

stop working automatically. If a water tower is used along with 

the automatic pump, connect to the upper limit switch and the 

pump will start or stop working automatically with water level 

in the water tower. 

2. MODEL DESCRIPTION

3. TECHNICAL DATA

 

Max. flow: 90Umin 

Max. head: 1 OOm 

Output power: 0.3-2.2kW 

Max. Suction: 9m 

Insulation grade:IP44 

Protection grade:F 

Max. ambient tempe40 

Max. liquid tempe40

4. IMPLEMENTATION STANDARDS

 

IEC/EN 60335-1 Household and similar electrical appliances-

-safety Part1: General requirements. 

IEC/EN 60335-2-41 Household and similar electrical 

appliances--safety Part2-41: Particular requirements for pump. 

2006/95/EC Low voltage directive

PEP

   

05

  

A  16 S

 

Hertz

 5=50hz, 6=60Hz    

Features

 S=Standard    

 

Series Peripheral Pump

Phase

 1=Single phase, 3=Three phase

 

Voltage

 A=115V, C=230V, F=110/220V

 

HPx10

1. To ensure normal and 

safety operation of the 

electric pump, read manual 

carefuly before use.

3. Do not touch the electric 

pump while working; do not 

wash, swim near working 

area or let livestock into the 

water to avoid accidents.

2. The electric pump should 

have reliable grounding to 

prevent short circuit; for 

safety, leakage protection 

switch should be equipped 

and be careful no to wet the 

power plug; socket should be 

connected in damp - proof 

area.

Manual 

1

0

0

1

ON

OFF

5. SAFETY PRECAUTIONS

Reviews: