background image

3

IMPORTANT SAFETY INSTRUCTIONS

PUMP

 

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

CAUTIONS:

The pump has been evaluated for use with water only.

Risk of electric shock.   

Do not remove cord and strain relief. Do not connect conduit to pump. 

Do not use the pump in water exceeding 86ºF / 30ºC.

Do not use the pump in flammable liquids. 

Do not use the pump for industrial purposes. 

Do not use the pump in vehicles or on board ships or aircraft or swimming pools.   

Do not use the pump in location where special conditions prevail, such as the presence of a corrosive or explosive atmosphere (dust, vapor or

 

gas).

Do not let the pump run dry. Pump must be completely submerged for proper operation and cooling.

Do not lift the pump by its power cord.

Keep the plug dry. Do not expose the plug to water or steam.

Before connecting to the power source, make sure that the pump is assembled and completely submerged in water.

Always disconnect the pump from the power source before performing any maintenance on the pump, lights (if equipped), or fountain.

Do not exceed the voltage shown on the pump.

Check the water level regularly to ensure the pump is completely submerged during operation. The pump should be fully submerged during 

operation.    Do not add water while operating the product.    Always disconnect the pump from the power source before adding water.

WARNINGS:

1.

Risk of electric shock. This pump is supplied with a grounding conductor and grounding-type attachment plug. To reduce the risk of electric 

shock, be certain that it is connected only to a properly grounded, grounding-type receptacle.

2.

To reduce the risk of electric shock, use only on portable self-contained fountains no larger than 5 ft / 1.52 m in any dimension.

3.

If equipped with a 3-prong, grounded type plug, do not remove the grounding pin from the plug on the power cord. 

CARE AND MAINTENANCE

ASSEMBLY INSTRUCTIONS

1.

Unpack the contents of the box and check to make sure that all items are accounted for and in good condition.

2.

Select a flat, level surface for the assembly and final location of your fountain.

3.

Place the main body on a flat, level surface. From the opening at the back of the fountain, insert the water supply tube into the pump outlet on

the top of the pump and connect the LED light with the light cable separately. Please place the pump upright into the basin and draw the pump 

power cord out through the opening and connect it to the transformer.(Fig. 1)

4.

Add clean water into the basin. The water level should be approximately 1 in. / 25 mm lower than the top edge of the opening at the back of the

basin. (Fig.2)

5.

Connect the transformer to a GFCI outlet and the product will begin to function as intended.

6.

If the pump runs with low or high water circulation Check and adjust the regulator dial or slide on the front of the pump. Adjust the dial/slide 

towards (+) to increase water flow or towards (-) to decrease water flow. (Fig. 3)

7.

The LED lights were pre-assembled, but they are replaceable . When replace them ,please refer to Fig.1.

8.

To eliminate the possibility of water damage around your fountain, check for leaks and excessive splashing after the initial setup of your fountain. 

It is highly recommended that this fountain be placed in an area where it cannot be damaged that might cause damaged with the fountain .

9.

Do not leave your fountain running for extended periods of time when no one is present to observe the performance.

10.

Check the area around your fountain on a regular basis to ensure that there is no leakage.

Summary of Contents for 201607PT

Page 1: ...PLEASE CALL CUSTOMER SERVICE support teamson com 1 BUDDHA FOUNTAIN WITH LED LIGHT 201607PT USE CARE GUIDE 1 800 935 3959 9am 5pm EST Mon Fri ...

Page 2: ...UIRED FOR ASSEMBLY ASSEMBLY INSTRUCTION No tools required 2 NOTE The diagrams shown are for illustrative purposes only and are not to scale 1x Pump PT 1020 A 1x B x 1 C D E Main Body Transformer GPU351200200WAOO Fig 3 ...

Page 3: ...ained fountains no larger than 5 ft 1 52 m in any dimension 3 If equipped with a 3 prong grounded type plug do not remove the grounding pin from the plug on the power cord CARE AND MAINTENANCE ASSEMBLY INSTRUCTIONS 1 Unpack the contents of the box and check to make sure that all items are accounted for and in good condition 2 Select a flat level surface for the assembly and final location of your ...

Page 4: ...thout a visible crack turn the pump off fill the fountain and let the fountain sit for one week If there is a crack it will appear white Remember to keep the water full as will evaporate over time Seal the leak with plastic epoxy or Clear Silicone II sealant 13 If the fountain is not in use for an extended period of time disconnect the power and empty all the water from the fountain Do not tip the...

Page 5: ...oducts which have been subject to negligence abuse accident misapplication tampering alteration or modification nor due to improper installation operation maintenance repair or storage nor to other than normal application use or service including but not limited to operational failures caused by corrosion rust or other foreign materials in the system or operation at pressures in excess of recommen...