44
Pos Limits
:
sets the threshold parameters for right adjacent channels
En
:
opens or closes the adjacent channels from one to six channels
Meas Type
selects measurements type as Total Pwr Ref or PSD Ref. Default is Total
Pwr Ref.
Total Pwr Ref
sets total power reference to be Manual or Auto
Auto the total power reference is set automatically
Manual the total power reference is set manually
Occupied Bandwidth (OBW)
Calculates the power within the whole bandwidth by integral operation and
computes the occupied bandwidth by this value based on the specified power ratio.
Default occupied bandwidth percentage is 99%.
Select OBW measurement under Meas function and press Meas Setup to set
corresponding parameters, which includes Max Hold, % Pwr, OBW Span, n dB and
Limits.
Max Hold
:
enables or disables the Max Hold, default is Off. When enabled, the
function of which is same as the one of Trace.
%
Pwr
:
sets the occupied bandwidth percentage, that is the percentage of signal
power occupied within integral bandwidth power.
OBW Span
:
sets the integral frequency range in main channel, span will be set as the
integral bandwidth
n dB
:
sets the n dB value for calculates the transmitting bandwidth
Limits
:
the menu includes OBW, CW Offs and ACP
OBW
:
sets the limitation to Occupied Bandwidth
CW Offs
:
sets the limitation to frequency offset
Chain Pwr
:
sets the limitation to channel power