Function Range Accuracy
Resolution
400 mV
4 V
40 V
400 V
± 0,3 % of rdg. + 1 dgt.
100 µV
1 mV
10 mV
100 mV
DC Voltage
1000 V
± 0,5 % of rdg. + 1 dgt.
1 V
400 mV
4 V
40 V
400 V
± 2,5 % of rdg. + 5 dgt.
100 µV
1 mV
10 mV
100 mV
AC Voltage (True rms)
750 V
± 1,0 % of rdg. + 3 dgt.
1 V
40 mA
400 mA
± 0,8 % of rdg. + 1 dgt.
10 µA
100 µA
DC Current
20 A
± 1,5 % of rdg. + 5 dgt.
10 mA
40 mA
400 mA
± 2,0 % of rdg. + 3 dgt.
10 µA
100 µA
AC Current (True rms)
20 A
± 2,0 % of rdg. + 5 dgt.
10 mA
400
Ω
4 k
Ω
40 k
Ω
400 k
Ω
4 M
Ω
± 0,5 % of rdg. + 1 dgt.
1,0
Ω
1
Ω
10
Ω
100
Ω
1 k
Ω
Resistance
40 M
Ω
± 1,0 % of rdg. + 2 dgt.
10 k
Ω
4 nF
40 nF
400 nF
± 2,0 % of rdg. + 3 dgt.
1 pF
10 pF
100 pF
Capacitance
4 µF
40 µF
400 µF
± 3,0 % of rdg. + 5 dgt.
1 µF
10 µF
100µF
40 mH
± 3,0 % of rdg. + 20 dgt.
10 µH
Inductance
400 mH
± 3,0 % of rdg. + 10 dgt.
100 µH
Features
•
Computer Interface & Software - let you interface the meter with your PC-compatible computer so you can log
measurements.
•
Analog Bargraph Display - indicates the magnitude of the input compared to the full-scale value of the
measurement range.
•
Dual-Display - allows the meter to show two p secondary readings simultaneously on the LCD. For the
measurement of AC Volt and Logic, "d" is displayed at the front of secondary display to measure and to readout
two different types of measurement at the same time.
Input Range Selection
Main Display
Secondary display
AC Voltage
AC Voltage
dB(m)
Logic HI/LO
DC
Voltage
•
Overload and Transient Protection - helps protect the meter from accidental overload on most ranges. "OL" is
displayed with flashing the bar-graph, when an input is too excess to display.
•
Back-Lit display - affords you of a more flexibility in your working area when turn the power to on. Back-Lit is
powered by a voltage supplied from Power supply (DPS).
•
Auto-Hold - freezes a reading automatically recorded 3 seconds ago, when last reading is completed. For the
measurement of DC Volt, Current, Diode, Capacitance "A" is displayed at the front of secondary display. When
this feature is turned on, the secondary display shows the reading taken 4 – 5 seconds earlier.
•
Min./Max/Data-Hold - let you keep a readings of minimum, maximum and captured value on the on the
sub-display, while showing the present readings on the main-display.
•
Range-Hold - sets the meter from auto-range to manual-range mode except capacitance position. In the manual-
range mode, each you press
UP DOWN
keys, the range and the input range annunciator increment and/or
decrements, and a new value is displayed.
•
Relative Offset - displays the difference between the stored value and subsequent readings. To set the reference
value, follow these steps:
- 32 -