-45-
4. DMM Measurement and Setup
4.1 DC Voltage Measurements
CAUTION:
Do not measure DC voltages if a motor in the circuit
is being switched ON or OFF. Large voltage surges may
occur that can damage the meter.
-
Set the function switch to the VDC position.
-
Insert the black test lead banana plug into the negative
COM jack.
-
Insert the red test lead banana plug into the positive
V jack.
-
Read the voltage in the display.
4.2
AC+DC Voltage Measurements
CAUTION:
Do not measure DC voltages if a motor on the
circuit is being switched ON or OFF. Large voltage surges
may occur that can damage the meter.
-
Set the function switch to the VDC position.
-
Insert the black test lead banana plug into the
negative COM jack.
-
Insert the red test lead banana plug into the
positive V jack.
-
Press the MODE key to switch the
V AC+DC
Voltage functions.
-
Read the AC+DC voltage in the display.