4. REL-button
Example:
If the stored Relative value is 20.00 V and the present measured
value is 22.00 V, the display shows a value of 2.00 V.
If the value is the same as the stored Relative value, the display
shows 0.00 V.
*
Press the „REL“ button to activate the REL-mode.
*
Auto range selection will be deactivated and the
present range will be stored.
*
Press „REL“ again to show the stored value..
*
Press and hold the „REL“-button for 1 second or turn
the rotary switch to remove the stored value and to
leave the „REL“-mode.
5. Hz/duty-button
When measuring ac voltage (or ac current), you can press this
button to select frequency, duty cycle or ac voltage (or ac
current) measurement function, and the display will show the
relevant symbol. In frequency or duty cycle measurement mode,
you can press this button to switch between frequency and duty
cycle measurements.
6. Max.-MIN
– HOLD Function
For measuring the MIN or Max-value make the following steps:
*
Press the „MIN MAX“ button to display the max.
measured value (MAX-Symbol appears in the LCD)
*
Press „MAX MIN“ again to display the min. measured
value (MIN-Symbol appears in the LCD)
*
Press „MAX MIN“ again to show the present measured
value (MAX MIN appears in the LCD).
*
Press and hold the „MAX MIN“ button for 1 second to
leave the "MIN MAX"-mode.