
Function Description
In scan mode, the current measurement is displayed on the main
display. The main display will hold the last values until the
tachometer automatically turns off.
*
Data Storage: Press the “MEAS” button until the reading
displayed on the LCD display. Observe the reading and press
the “MEM” button at the same time with the MEAS-button to
record. The maximum, minimum, average and data during
one shot measurement will be stored into a memory set. Then
the Data number will increase by one.
* Recall
Data: Use the “MEM” button to scroll and view the
stored data poi
nt. Press the “MEM” button once to next
storage, you will view the MAX measurements, MIN
measurements,
AVG
measurements
and
DATA
measurements. Press the “MEM” button and don’t to release it
to leap to next Data Set. You will view Data0 to Data9,10
selectable Data measurements.
-23-