-32-
To start the measurement, press the test button again. The test is
now carried out continuously, depending on the previously settled
test time (see 6.2 Test time setting). After the measurement has
been taken, the insulation measuring device discharges itself and
the measured values are shown on the display. These can be
saved by pressing the Enter / Save button (see 6.3 Saving
measured values). You reach the main screen by pressing the ESC
key.
The measurement can be stopped or canceled at any time by
pressing the Test / Stop button.
5.3 AC / DC voltage measurement
With the insulation measuring devices PeakTech 2680 A and
PeakTech 2685 A you are able to measure AC / DC voltage in the
range of 30 - 600 volts. Set the selector switch to the measurement
function V AC / DC (30 ~ 600V). Connect the test leads to the +HV
and
–HV sockets. Depending on the measurement, the display
shows the DC voltage value and for AC voltage measurements, the
measured frequency is shown at the same time.