Buzzer sound below under 10
Ω
(on 20
Ω
range)
Withstand voltage
meet EN 61010 safety requirements
category III
Dimensions (WxHxD) 170x165x92 with housing front cover
Weight
1,04 kg
Standard
accessories
test leads, alligator clips, carrying belt,
batteries and manual
8. Maintenance
CAUTION:
Always disconnect the test leads from the instrument before
attempting battery or replacement.
8.1. Batteries replacement
When the LCD shows the low battery flag, the batteries need
replacing. Eight batteries (AA or equivalent) are required.
Alkaline types are recommended. Open the battery
compartment lid on the back of the instrument by unscrewing
the screw. Replace all eight batteries with new ones observing
the correct polarity. Close the battery compartment lid and
replace the screw before using the tester.
8.2. Fuse replacement
Open the battery compartment lid. Remove the fuse conver
and the old fuse and replace with the new one. Replace the
fuse conver and screw the battery compartment lid back on
before using the tester.
-12-