PEAKnx 019-A17-00020 User Manual Download Page 27

www.peaknx.com

27

 EN USB-Connector User Manual

PEAKnx 
a DOGAWIST Investment GmbH Division 
Otto-Röhm-Straße 69 
64293 Darmstadt 
Germany

About PEAKnx

PEAKnx is an innovative company from Darmstadt, Germany (www.peaknx.com) and a 
manufacturer of solutions for home and facility automation. As the newest division of the 
PEAK corporate group, PEAKnx offers innovative hardware and software components for 
modern building control – such as individual front-end panels, which make a smart home’s 
full information available to home-owners at one central point. PEAKnx places great value 
on the qualitative interplay of design and functionality along the way.

The facility automation experts also offer associated services – from construction project 
planning, through consultation, to installation and realization by certified partners. The aim 
of PEAKnx is to make its customers’ everyday life more convenient, safe and economical. 
Along the way, the company can draw on more than 20 years of experience within the PEAK 
corporate group. 
In addition, PEAK is premium sponsor of SV Darmstadt 98 and, with this association, is 
committed to social projects in the Darmstadt region.

Service & Support: +49-6151-279 1825 
Sales & Administration: +49-6151-279 1824 
Web: www.peaknx.com 
Email: [email protected]

Summary of Contents for 019-A17-00020

Page 1: ...USB Connector DE Bedienungsanleitung EN User Manual...

Page 2: ...ene Software 6 2 3 1 Bus Monitor 6 2 3 2 IP Router 7 2 3 3 Installation der enthaltenen Software 7 2 3 4 Engineering Tool Software ETS Setup 8 2 4 Spannungsversorgung 8 3 Anschluss an den KNX Bus 8 3...

Page 3: ...onnector Bedienungsanleitung Seite Abbildungsverzeichnis Abbildung 1 KNX WAGO 243 211 Adapter 9 Abbildung 2 KNX WAGO 243 211 Adapter vergossen 9 Abbildung 3 Ma zeichnung des USB Connectors 12 Abbildun...

Page 4: ...cht ausdr cklich durch und gekennzeichnet DOGAWIST Investment GmbH PEAKnx a DOGAWIST Investment GmbH Division Otto R hm Stra e 69 64293 Darmstadt Deutschland www peaknx com info peaknx com Dokumentver...

Page 5: ...1 1 und 3 1 2 genutzt werden Mit Hilfe des im Softwarepaket enthaltenen Bus Monitors und IP Routers k nnen u a Telegramme des KNX Busses ausgelesen oder auf diesen gesendet werden Dazu bitte die Softw...

Page 6: ...gen verbunden werden Der USB Connector kann ohne Vorbereitung vom USB Anschluss des Computers entfernt werden Mehr Informationen zur Belegung des D Sub Steckers befinden sich im Anhang Abbildung 4 Wei...

Page 7: ...IP Client z B ETS der den IP Router verwenden kann mit einem KNX Netzwerk kommu nizieren Aus der KNX Spezifikation wird der IP Router als KNXnet IP Router ein KNXnet IP Ger t der Klasse B klassifizie...

Page 8: ...tisch installiert Wenn der USB Connector direkt am Laptop angeschlossen und der ETS Bus Monitor verwendet wird ist es m glich nur das ETS Setup auszuf hren Dazu wie folgt vorgehen Den Tab INSTALL ffne...

Page 9: ...senen Linie dem Netzwerk Der vorhandenen Spannung auf dem Bus am Anschlussort Die Leitung muss mindestens eine Spannung von 21 V DC aufweisen damit die Busteilnehmer fehlerfrei arbeiten k nnen Aufgrun...

Page 10: ...tatus Ja Einfaches Aufleuchten USB Connector wird verbunden LED Test Gr n Langsames Blinken USB Connector ist verbunden und Treiber geladen Gr n Schnelles Blinken USB Connector empf ngt Daten Nein USB...

Page 11: ...B 32 Bit 2GB 64 Bit Festplattenspeicher 1 GB Grafik DirectX 9 oder neuer NET Version ID 4 5 1 enthalten in Windows 8 1 10 Ma e Gr e des Interface 86 x 42 5 x 20 5 mm Gewicht des Interface 88 g Umgebun...

Page 12: ...www peaknx com 12 DE USB Connector Bedienungsanleitung Abbildung 3 Ma zeichnung des USB Connectors Abbildung 4 D Sub Pin Belegung Anhang Ma zeichnung...

Page 13: ...chter Elektro Elektronik Altger te Elektro Elektronik Altger te k nnen gef hrliche Stoffe enthalten die f r die Gesundheit und die Umwelt sch dlich sind oder wertvolle Stoffe enthalten die der Wiederv...

Page 14: ...www peaknx com 14 DE USB Connector Bedienungsanleitung Notizen...

Page 15: ...d Funktionalit t Die Experten f r Hausautomation bieten auch die dazugeh rigen Dienstleistungen von der Planung des Bauvorhabens ber die Beratung bis hin zur Installation und Realisierung durch zertif...

Page 16: ...software 20 2 3 1 Bus Monitor 20 2 3 2 IP Router 21 2 3 3 Installation of included software 21 2 3 4 Engineering Tool Software ETS Setup 21 2 4 Power supply 22 3 KNX Bus connection 22 3 1 KNX connecti...

Page 17: ...USB Connector User Manual Page List of Figures Figure 1 KNX WAGO 243 211 Adapter 22 Figure 2 KNX WAGO 243 211 Adapter encapsulated 22 Figure 3 Dimensioned drawing of the USB Connector 26 Figure 4 D S...

Page 18: ...es They are not explicitly marked by or DOGAWIST Investment GmbH PEAKnx a DOGAWIST Investment GmbH Division Otto R hm Stra e 69 64293 Darmstadt Germany www peaknx com info peaknx com Document version...

Page 19: ...ncluded in the software package enable the user to for example read or send telegrams on the KNX bus Please note the software requirements of the Windows device see section 2 1 System requirements to...

Page 20: ...ormation on the Pin assignment of the D Sub connector is located in the appendix figure 4 More information about the adapters can be found in section 3 1 2 3 Included software The scope of delivery in...

Page 21: ...on of a KNXnet IP router Device Management Tunneling Routing 2 3 3 Installation of included software The software package includes an IP Router a Bus Monitor and the ETS Setup The IP Router acts as a...

Page 22: ...ply In general the device is operated internally with a supply voltage of 5 V DC However the device function is only available when the KNX bus is connected according to the KNX specification 3 KNX Bu...

Page 23: ...C The distance between two participants is a maximum of 700 meters The number of bus subscribers is determined on the one hand by the power supply used on the other hand by the number of free addresse...

Page 24: ...side 5 V DC KNX side 24 V DC Max Power usage USB 100 mA Ports USB 1 x USB connector type A Fieldbus 1 x D Sub 9 Pin male Software requirements ETS compatible ETS 5 Operating system Windows 10 8 1 7 3...

Page 25: ...r Manual Environment Operating temperature 40 C to 85 C Temperature for transport and storage 40 C to 100 C Relative humidity 15 to 90 no condensation Protection class DIN EN 60529 IP20 EMC 2014 30 EU...

Page 26: ...www peaknx com 26 EN USB Connector User Manual Appendix Dimension drawings Figure 3 Dimensioned drawing of the USB Connector Figure 4 D Sub Pin Assignment...

Page 27: ...central point PEAKnx places great value on the qualitative interplay of design and functionality along the way The facility automation experts also offer associated services from construction project...

Page 28: ...www peaknx com 28 DE USB Connector Bedienungsanleitung www peaknx com...

Reviews: