background image

Insulation Test

24

Turn the rotary switch to OFF and remove the test leads from the terminals.

1

Screw

2

Battery

Specifications

Complies with IEC/EN 61010-1 1000V CAT III 600 V CAT IV.

1000V DC Voltage

750V AC Voltage.

Summary of Contents for PM5205

Page 1: ...witch 9 Input Terminal 9 Function Description 9 Power Up Options 9 Automatic Power Off 10 Hold Funcion 10 Relative Measurement 10 Insulation Test Lock 11 Storing Test Data 11 Reading Test Data 12 Dele...

Page 2: ...II Measuring Resistance 21 Insulation Test 22 Replacing battery 23 Specifications 24 Accuracy 26...

Page 3: ...than the rated voltage as marked on the Meter between the terminals or between any terminal and earth ground Use caution with voltages above 30 V ac rms 42 V ac peak or 60 V dc These voltages pose a...

Page 4: ...warranted for 12 months except for misused altered neglected contaminated or damaged by accident or abnormal conditions of operation or handling This warranty does not apply to fuses disposable batte...

Page 5: ...s which could lead to possible electric shock or personal injury replace the battery as soon as the low battery indicator appears Indicates a test lock will be applied the next time you press Test But...

Page 6: ...st mode display the PI value Timer function is selected Store function is selected View the memory data when the data is invalid display DC Voltage function is selected AC Voltage function is selected...

Page 7: ...resent the sign alternate on or off Source voltage rating for insulation test Timer unit Measure unit Display the Max Min Avg value Display Messages Indicator Description batt Appears on primary displ...

Page 8: ...n insulation mode indicates the meter performs the auto discharge function not to touch any input terminals in this mode SAVE Store measuring data dEL n Delete the selected data dEL ALL Delete all mem...

Page 9: ...Insulation Tester 7 Buttons...

Page 10: ...insulation mode to view max value min value avg value upper limited value lower limited value preset timer DAR PI 4 Confirm Button 5 Back Light on Off when the light turn on after 10s the meter auto t...

Page 11: ...al except Inuslation measure LO Common terminal in Inuslation measure Function Description Power Up Options Holding a button down while turning the Meter on activates a power up option Power up option...

Page 12: ...ion test mode or if the auto power off feature has been disabled by pressing SELECT button when the Meter is turned on Hold Funcion Press Hold button to freeze the displayed value Press again to relea...

Page 13: ...ss Test button again The test lock will unlocked while to cancel insulation test Lock function is invalid when timer function is selected Storing Test Data Press MEMO button the meter enter Hold statu...

Page 14: ...Automatic Power Off 12 Reading Test Data Press READ button to display the data in memory Press button to change the code and read the data accordingly...

Page 15: ...Data In READ mode press ENTER meter display dEL n press enter button again to delete selected data press READ button to delete all data The meter will beep once the data is deleted Press other button...

Page 16: ...limited value COMP function is invalid meter display Press COMP button to view the upper and the lower limited value The meter display COMP and display HI or LO on secondary screen as below When the...

Page 17: ...Insulation Tester 15...

Page 18: ...The timer function can only be activated in the insulation test Enable the TIMER function by pressing TIMER the meter display TIMER the lock function will be invalid and the meter starts the insulati...

Page 19: ...ay The meter just display the test voltage when it is under the insulation test to check the time please press button Press SELECT to check the preset time The LCD screen display TIMER PRES is shown o...

Page 20: ...18 MAX MIN AVG In test mode Press Select button to view max min average value In hold mode press select button to review max min average value...

Page 21: ...measured 10 minutes after applying the test voltage R1Min R60Sec Resistance value measured 10 minutes after applying the test voltage R15Sec Resistance value measured 10 minutes after applying the te...

Page 22: ...MAX MIN AVG 20 to circuit Measuring AC Voltage Switch rotary switch to V position Input terminals and test leads connecting as follows figure then connect test leads to circuit...

Page 23: ...lation Tester 21 Measuring Resistance To avoid possible damage to the Meter or to the equipment under test disconnect circuit power and discharge all high voltage capacitors before testing for continu...

Page 24: ...itch to prevent damage to the meter Insulation tests should only be performed on dead circuits Check the test leads before testing Switch rotary to Insulation position if meter display please replease...

Page 25: ...h the Meter the meter display DISC The secondary Display 0 VDC indicator when the voltage discharge finished Disconnect the test leads from circuit Replacing battery To avoid false readings which coul...

Page 26: ...on Test 24 Turn the rotary switch to OFF and remove the test leads from the terminals 1 Screw 2 Battery Specifications Complies with IEC EN 61010 1 1000V CAT III 600 V CAT IV 1000V DC Voltage 750V AC...

Page 27: ...nds on and 25 seconds off Insulation Measurement Range 0 01 M to 100 0 G Insulation Test Voltages 250 500 1000 2500 V Insulation Source Voltage 20 0 Insulation Short Circuit Test Current 3 0mA nominal...

Page 28: ...n Test 26 Accuracy DCV RANGE RESOLUTION ACCURACY 200V 0 1V 0 5 5 1000V 1V 0 5 5 ACV RANGE RESOLUTION ACCURACY 50 60Hz 200V 0 1V 1 5 5 750V 1V 1 5 5 Resistance RANGE RESOLUTION ACCURACY 20 0 01 1 5 200...

Page 29: ...0 20 0 20M 0 01 M 3 rdg 5dgt 20 M 200M 0 1M 200 M 250 M 1M 500V 0 20 0 20M 0 01 M 3 rdg 5dgt 20 M 200M 0 1M 200 M 500M 1M 1000V 0 20 0 20M 0 01M 3 rdg 5dgt 20 M 200M 0 1 M 200 M 1000M 1 M 2500V 0 20 0...

Reviews: