4.1.1
Receive/Transmit Tab
The
Receive/Transmit
or
Receive/Publisher
tab is the main element
of PLIN-View Pro. It contains two lists, one for received LIN
messages and one for to be transmitted ones. In Master mode,
Receive/Transmit appears and LIN messages can be transmitted
onto the bus. In Slave mode, Receive/Publisher appears. In this case
it is not possible to transmit messages.
If a Master requests data from a Slave, the Slave can publish the
data within the LIN frame. The Global Frame Table contains all
entries for defined LIN frames that can be used by the LIN interface.
In order to transmit a LIN frame, the basic frame definition in the
properties must be adapted.
Do the following to transmit a LIN frame with PLIN-View Pro:
1.
From the
Global Frame Table
, select a frame.
2.
Change the
Checksum Type
property to
Enhanced
or
Classic
.