![Peak PCAN-USB FD User Manual Download Page 6](http://html1.mh-extra.com/html/peak/pcan-usb-fd/pcan-usb-fd_user-manual_1517255006.webp)
PCAN-USB FD – User Manual
6
Time stamp resolution 1
μ
s
CAN-Bus connection via D-Sub, 9-pin (in accordance with
CiA® 102)
FPGA implementation of the CAN FD controller
NXP TJA1044GT CAN transceiver
Galvanic isolation up to 500 V
CAN termination can be activated through a solder jumper
Measurement of bus load including error frames and overload
frames on the physical bus
Induced error generation for incoming and outgoing CAN
messages
5-Volt supply to the CAN connection can be connected through a
solder jumper, e.g. for external bus converter
Voltage supply via USB
Extended operating temperature range from -40 to 85 °C
(-40 to 185 °F)
Note:
This manual describes the use of PCAN-USB FD adapter
with
Windows
. You can find device drivers for
Linux
and the
corresponding application information on the provided DVD in
the directory branch
Develop
and on our website under