NM60L- Nitrogen Gas Generator 

UM – NM60L

 

 

 

 

 

Warranties & 

Liabilities

 

 

 

 

Warranties and Liabilities

 

 

1.   The Company warrants that it has title to the Goods. 

 

2.   Subject to the provisions of this clause the Company warrants that the Goods shall comply in all material respects 

with any specification referred to in the Order Confirmation (as the same may be amended) and shall, subject 

thereto, be free from defects in material and workmanship for the lesser of a period of twelve months from the date 

of delivery or thirteen months from the date of dispatch from the factory. 

 

3.   Save as provided in this clause and except where the Goods are sold to a person dealing as a consumer (within 

the meaning of the Unfair Contract Terms Act 1977) all warranties, conditions or other terms implied by statute or 

common law are hereby expressly excluded save to the extent they may not be lawfully excluded.  When the 

Goods are sold to a consumer within the meaning of the Unfair Contract Terms Act 1977 their statutory rights are 

not affected by the provisions of this clause. 

 

4.   In the event of the Customer making a claim in respect of any defect in terms of clause 2 hereof the Customer 

must:- 

4.1. reasonably satisfy the Company that the Goods have been properly installed, commissioned, stored, serviced 

and used and without prejudice to the generality of the foregoing that any defect is not the direct or indirect result 

of  lack  of  repair and/or servicing,  incorrect  repair and/or  servicing,  use of  wrong materials  and/or  incorrect  spare 

parts; and 

4.2. allow the company to inspect the Goods and/or any installation and any relevant packaging as and when 

reasonably required by the Company. 

 

5.   Subject to the Company being notified of any defect as is referred to in sub-clause 2 hereof within a reasonable 

time  of  it  becoming apparent  and  subject  always  to  the  terms  of sub-clause  4  hereof,  the  Company  shall,  in  its 

option, replace or repair the defective Goods or refund a proportionate part of the Price.  The Company shall have 

no further liability to the Customer (save as mentioned in sub-clause 6 hereof). 

 

6.   The Company shall be liable to indemnify the Customer in respect of any claim for death or personal injury to any 

person in so far as such is attributable to the negligence or breach of duty of the Company or any failure by the 

Company to comply with the provisions of sub-clause 2 hereof. 

 

7.   Save as provided in sub-clause 2 hereof the Company shall not be liable in respect of any claim by the Customer 

for  costs,  damages,  loss  or  expenses  (whether  direct,  indirect,  consequential  or  otherwise)  or  indemnity  in  any 

respect howsoever arising including, but not by way of limitation, liability arising in negligence (other than pursuant 

to clause 6 above) that may be suffered by the Customer or any third party. 

 

 

 

SAFETY NOTICE TO USERS

 

These instructions must be read thoroughly and understood before installation and 

operation  of  your  Peak  Scientific  NM60L.  Use  of  the  Generator  in  a  manner  not 

specified by Peak Scientific MAY impair the SAFETY provided by the equipment. 

When handling, operating or carrying out any maintenance, personnel must employ 

safe   engineering   practices   and   observe   all   relevant   local   health   and   safety 

requirements and regulations. The attention of UK users is drawn to the Health and 

Safety at Work Act 1974, and the Institute of Electrical Engineers regulations.

 

 

WARNING: 

Nitrogen  is  not  a  poisonous  gas,  but  if  the  concentration  in  the 

inhaled air becomes too high there will be a risk of asphyxiation.

 

 

 

 

Summary of Contents for NM60L

Page 1: ...NM60L NITROGEN GAS GENERATOR USER MANUAL UM NM60L 19 Rack ...

Page 2: ...y Page No 3 Warranty Statement 4 Safety Notice to Users 4 Declaration of Conformity 5 Air Connection 6 Principle of Operation 7 Commissioning 8 Maintenance Schedule 9 Technical Specifications 12 Pneumatic Diagram 13 Over Dimension 14 Maintenance Log 15 Notes 16 2 ...

Page 3: ...ls Date 1 Document Created H D 30 05 03 2 USA Technical support number updated FAD 10 11 04 3 Document Updated FAD 11 03 05 4 New Style Front Added FAD 08 04 05 5 Added Overall Dimension S Khan 05 06 08 6 Updated Diagram S Khan 05 05 10 7 Filter Info Update LC 01 05 13 3 ...

Page 4: ...the Company 5 Subject to the Company being notified of any defect as is referred to in sub clause 2 hereof within a reasonable time of it becoming apparent and subject always to the terms of sub clause 4 hereof the Company shall in its option replace or repair the defective Goods or refund a proportionate part of the Price The Company shall have no further liability to the Customer save as mention...

Page 5: ...contacting us through info peakscientific com WEEE Statement of Compliance WEE FjQ I1 16 X1U The WEEE Waste of Electrical Electronic Equipment Directive 2002f96 EC issued by the European Union aims to reduce the impact upon the envirronment from disposal of certain types of equipment It requires producers to in plement controls to ensure that eq uipment that they produce is correctly disposed of f...

Page 6: ...ogen Outlet connections are at the rear of the generator in the middle right side of the panel The Air inlet connection is the left port 3 8 BSP female outlet port is 1 4 BSP female The generator is supplied with two Breathing Air pre filters and an Activated Carbon post filter which are fitted internally The Breathing Air filters will drain moisture and are equipped with automatic drains This is ...

Page 7: ...ermeate through the membrane wall whilst so called Slow gases will not and continue along the membrane tube and are thus available for collection and use Air passes into the system via the Breathing Air Filter This will prevent bulk moisture and harmful contaminants from reaching the Membrane The clean air then passes into the Membranes where Oxygen CO2 and Moisture are removed allowing High Purit...

Page 8: ... and pressure Once the Membrane reaches the design pressure the Generator will stabilise and produce pure Nitrogen Maximum purity will be achieved after around 1 hour After this time the generator can be re connected to the application The design of the generator is that it will deliver up to rated output flow of Nitrogen at 100 psig Should the demand for Nitrogen be less than the rated output flo...

Page 9: ...ipment it should be regularly inspected and serviced as below BA Inlet Filters Every 12 months RAC Filter Elements Every 12 months BA Inlet Filter Elements These should be changed at 12 months intervals In addition filter bowls should be cleaned and the operation of the auto drains should be checked if auto drain requires replacing Part is 02 4485 FAILURE TO FOLLOW THE PRESCRIBED MAINTENANCE PLAN ...

Page 10: ...nerator MUST be turned OFF and the Generator MUST be de pressurised prior to attempting to remove ANY filter bowl Failure to do this may cause injury Inlet Breathing Air Filter Separator Elements The top Filter Element 00 4427 should be changed at 12 month intervals The bottom element should be changed at 12 month intervals The Part Numbers are as shown in the drawings below RAC Element Prt 00 442...

Page 11: ...turned OFF and the Generator MUST be de pressurised prior to attempting to remove ANY filter bowl Failure to do this may cause injury R A C Elem ent P rt 00 4425 The filter housing is removed by un screwing in a counter clockwise direction IMPORTANT Ensure that the system is NOT under pressure before attempting to remove the bowl and that the air supply is shut off 11 ...

Page 12: ...m Air Inlet Flow Rate 180 l min ATP Outlet Gas Maximum Pressure Drop Outlet Inlet δP 8 psig Maximum Gas Outlet Pressure 100 psig Maximum Outlet Flow High Purity Nitrogen 60 Litres min ATP Start up time for Purity 60 minutes Particles 0 01um Serviceable Parts List Service Kit Part 08 4429 Breathing Air Inlet Filter Elements 00 4424 00 4427 Active Carbon Filter Element 00 4425 General Dimensions W x...

Page 13: ... 0 I J c 3 II A l dM Switch Safety Valve Nort ReturnValve Membranes Inlet Valve Receiver Inlet BA Filter Pressure Regulator Flow Controller RAC Filter w NM 60L System Diagram ...

Page 14: ... II NM60L Nitrogen Gas Generator Overall Dimensions 23 38 inch 594 0 mm c Overall Dimensions cr II II Ill E ISOMETRIC VIEW 14 ...

Page 15: ...NM120L Nitrogen Gas Generator UM NM60L Maintenance log Maintenance Log Model NM60L Serial number Work Done Remarks Date Name 15 ...

Page 16: ...Notes 16 ...

Reviews: