Installation and Operating handbook 

 

DLA200 Dual Line Amplifier Unit 

 
 

Summary of Contents for DLA200

Page 1: ...714200 Fax 01484 723666 IMPORTANT NOTE THE INFORMATION AND SPECIFICATIONS CONTAINED IN THIS DOCUMENT SUPERCEDE ALL PREVIOUSLY PUBLISHED INFORMATION CONCERNING THIS PRODUCT PEAK COMMUNICATIONS Ltd main...

Page 2: ...d manner will invalidate compliancy to these standards Safety To ensure safety of operator the DLA200 units have been designed to comply with the following safety standard EN 60950 Safety of informati...

Page 3: ...near the equipment and easily accessible or that there should be another suitable means of disconnection from the mains supply The equipment is designed to operate from a TN type power supply system...

Page 4: ...K 2 GREEN Line amplifier OK and ONLINE AMBER Line amplifier OK and OFFLINE RED Line amplifier failure see rear panel interface connector for condition PSU 1 GREEN mains input present RED mains input f...

Page 5: ...des from the single mains input SLOT DESIGNATIONS The Slots for the MBX units are designated Unit 1 and Unit 2 looking from the front of the unit the RHS slot is for unit 1 and the LHS slot is for uni...

Page 6: ...ct in reading data 4 3 2 1 Address 0 0 0 0 32 1 0 0 0 33 0 1 0 0 34 1 1 0 0 35 0 0 1 0 36 1 0 1 0 37 0 1 1 0 38 1 1 1 0 39 0 0 0 1 40 1 0 0 1 41 0 1 0 1 42 1 1 0 1 43 0 0 1 1 44 1 0 1 1 45 0 1 1 1 46...

Page 7: ...ches see earlier I Instruction number The possible instructions are STATUS REQUEST character 32 STATUS REPLY character 33 CONFIGURE character 34 MESSAGE numerous characters from length 0 upwards If no...

Page 8: ...unit STATUS REPLY Instruction 33 Message body all bytes chars Description Values Position of the UNIT SELECT switch A or B or O O AUTO A UNIT A B UNIT B Position of the remote local switch R or L R R...

Page 9: ...e has been received by the unit a Status reply message will be sent back by the unit The command will only change the state of the unit IF the unit is in REMOTE mode The actual position of the switch...

Page 10: ...twork its settings can be configured to suit the application needs SNMP Agent with MIB II RS 232 Like Group The DBU series units fitted with Ethernet have a built in SNMP Simple Network Management Pro...

Page 11: ...cards UDP MIB TCP MIB SNMP MIB UdpInDatagrams tcpRtoAlgorithm snmpInPkts UdpNoPorts tcpRtoMin snmpOutPkts UdpInErrors tcpRtoMax snmpInBadVersions UdpOutDatagrams tcpMaxConn snmpInBadCommunityNames Udp...