background image

Page 20

Page 20

Go Online or Complete and Return

You can register for your 

FREE 12 month Warranty 

with ease online at 

www.peakscientific.com/protected.

Alternatively, you can send the completed form to Peak Scientific by post or 
email at [email protected].

Important!

You have 

1 month to register

 your Peak Scientific product from the date of 

installation. Once registered the warranty will be honoured for a period of 12 

months. If you wish to defer the installation of your generator, you must notify 

Peak Scientific immediately by emailing [email protected]. For 

generators that remain unregistered after 1 month from the shipment date, the 

warranty will be considered active from the date of factory dispatch.

Go Online or Complete and Return

You can register for your 

FREE 12 month Warranty 

with ease online at 

www.peakscientific/protected

.

Alternatively, you can send the completed form to Peak Scientific by post or 
email at 

[email protected]

.

Product Warranty Registration

Contact name

Email address

Company

Address

City/town

Postcode

Country

Telephone

Generator serial #

Model type

Installation date

Do you still use an 

alternative gas solution i.e. 

cylinders or bulk liquid?

Yes                 No

What gas requirements do 

you have in your lab?

Hydrogen             Nitrogen            Zero Air

Extend your cover with

Peak Scientific offer comprehensive gas generator after sales support packages.  

Peak [Protected] aftercare support can guarantee an on-site response within 

72 hours*, genuine parts from our ISO9001 approved factory and a 95% first-time 

fix rate.  See our enclosed Peak [Protected] leaflet for further information.

Important!

You have 1 month to register your Peak Scientific product from the date of installation. Once registered 

the warranty will be honoured for a period of 12 months. If you wish to defer the installation of your 

generator, you must notify Peak Scientific immediately by emailing [email protected]

For generators that remain unregistered after 1 month from the shipment date, the warranty will be 

considered active from the date of factory dispatch.

* Complete Plan only

Summary of Contents for Precision Hydrogen

Page 1: ...Precision Hydrogen Installation Guide Rev 4 RSID 2370 PN IG PREC H2PCB EN 18 01 22 Precision Hydrogen All Colour Screen Models Installation Guide...

Page 2: ...allation guide is intended to be used as a step by step quick start guide to facilitate installation and configuration Please visit www peakscientific com downloads to download the full User Manual fo...

Page 3: ...er the protection provided by the equipment may be impaired WARNING WARNING WARNING WARNING CAUTION Safety Notices Peak Scientific Instruments cannot anticipate every possible circumstance which may r...

Page 4: ...m x1m x1 Tygon Tubing 05 3131 Barbed Fitting 05 7029 Page 4 US Mains Cable C13 5 15 04 1039 US Mains Cable C13 6 15 04 1029 Teflon Tubing 00 4411 4L Water Bottle 10 9016 x1 See Section 14 Regarding Co...

Page 5: ...position on a flat surface in desired area WARNING the weight of the unit constitutes a two man lift Safe lifting practices are advised 1 2 Ensure that there is at least 7 5 cm of space to the sides...

Page 6: ...bing must be clean grade copper or stainless steel only Copper Stainless Steel only Hydrogen Trace Hydrogen Copper Stainless Steel only 4B Copper Stainless Steel only 3 Remove the two Transit Plugs fr...

Page 7: ...use the supplied Teflon Tubing 5A Hydrogen Trace Hydrogen 5B 00 4411 00 4411 00 4411 00 4411 6 The Tygon Tubing and Barbed Fitting supplied in the generator fittings kit should be connected to the Fil...

Page 8: ...Grade De Ionised Water 1 S cm 20 C If using a Peak Water Bottle connect the remaining Barbed Fitting from the fittings kit to the other end of the Tygon Tubing If using an alternative water bottle co...

Page 9: ...Page 9 9 After the bottle has been rinsed it should be filled with High Grade De Ionised Water 10 CAUTION Once the bottle has been filled replace the lid...

Page 10: ...end of the Tygon Tubing to the connection on the top of the filled Water Bottle ensuring there is a secure connection Ensure the lid is securely fastened by turning it clockwise and that the air hole...

Page 11: ...ns cable from the fittings kit and plug the IEC 60320 C13 cable into the mains input at the rear of the generator Please note both 110V and 230V US cables have been supplied ensure correct mains cable...

Page 12: ...n the back of the unit Plug the mains cable into an appropriate 100 230VAC 50 60Hz single phase power supply CAUTION ensure the correct cable has been selected for your electrical supply 100 230VAC 50...

Page 13: ...ow run diagnostics and a leak detection test Note In the unlikely event that diagnostics are unsuccessful an alarm will sound and a yellow failure screen will be displayed complete with a mute button...

Page 14: ...ctively Press the SAVE button to store the new value 20 Upon successful completion of the diagnostic checks the home screen will be displayed The user should now select MENU System State Standby Press...

Page 15: ...it of measure and pressure have been selected pressing HOME will return the user to the home screen 22 Pressing START will start the supply to the application The unit may take a few minutes to adjust...

Page 16: ...return the generator to Standby mode 24 The unit will now maintain the desired pressure while the application is supplied System State Running Pressure Target Current Units 25 00 25 00 psi Stop Menu S...

Page 17: ...enerators hydrogen outlet to the Application Before connecting the generator to the application it is recommended to purge the generator to atmosphere for a maximum period of 10 minutes to evacuate an...

Page 18: ...rator is now fully installed operational and ready to supply gas on demand to your instrument 27 It is recommended that any Precision Trace unit is left to run for 24 hours and the Hydrogen unit is le...

Page 19: ...recommended Extended periods at extremes can have a detrimental effect on the operation and life of the Generator Ensure that all pipework between generator and equipment is checked for leaks Please...

Page 20: ...arranty peakscientific com Product Warranty Registration Contact name Email address Company Address City town Postcode Country Telephone Generator serial Model type Installation date Do you still use...

Page 21: ...Page 21...

Page 22: ...Page 22...

Page 23: ...Page 23...

Page 24: ...ry continent around the world This allows us to provide an industry leading rapid response service to our customers With Peak Protected your laboratory s productivity becomes our top priority To discu...

Reviews: