Genius1025 Installation Guide Rev 4 PN IG-0039  RSID 2858 EN 

 

21/7

/

22

Genius 1025

Installation Guide

Summary of Contents for Genius 1025

Page 1: ...Genius1025 Installation Guide Rev 4 PN IG 0039 RSID 2858 EN 21 7 22 Genius 1025 Installation Guide ...

Page 2: ...gu ation of your Peak Scientific gas gene ator For more extensive user operation directions we recommend you download the User Manual from the website Please visit www peakscientific com downloads to download the full User Manual for your gas generator Thank you for selecting Peak Scientific o meet your laboratory gas generation needs and should you require any further assistance or support please...

Page 3: ...A CAUTION notice denotes a hazard It calls attention to an operating procedure process or similar which if not correctly performed or adhered to could cause damage to the Generator or the Application Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood or met Caution risk of electric shock Ensure power to the Generator has been removed before proceeding Safety...

Page 4: ...ains Cable C19 6 15 04 1024 x1 EU Mains Cable C19 04 1026 x3m 6mm OD x 4mm ID PE 00 1282 x1 8mm Hex Key 00 0007 PTFE Tubing 00 1266 2x3m Fittings Kit x2 Compression Fitting 02 4421 x1 6mm Push Fit Fitting 02 4600 x2 Flow Control SIlencer 02 1096 ...

Page 5: ...osition on a fl t surface in desired area 1 2 First remove the compressor transit brackets These can be accessed by removing the generator side panels Starting with the left hand side panel use the 8mm Hex Key 00 0007 and turn the lock 90 to the right 00 0007 ...

Page 6: ...er middle of the panel 4 The transit bracket is located below the compressor and has a sticker on it stating Remove before use To remove the transit bracket remove the four screws as indicated then slide the bracket out from underneath the compressor Please retain the bracket and screws for future transportation ...

Page 7: ...Page 7 6 5 Repeat step 4 to remove the right hand side transit bracket Follow the same process to remove the right hand side panel ...

Page 8: ...encer 02 1096 fittings o the Nitrogen and Dry Air Ports Connect the 6mm PE Tubing 00 1282 to the 6mm Push Fit Fitting 02 4600 Fit the other end of the tubing to a suitable drain connection or container The container MUST NOT have an airtight seal as water and air will be expelled periodically under a slight pressure 02 4600 00 1282 02 1096 ...

Page 9: ...ingle phase power supply CAUTION ensure the correct cable has been selected for your electrical supply UK EU US 230V 04 1024 04 1025 04 1026 CAUTION Select the appropriate IEC 60320 C19 mains cable from the fittings kit and plug the cable into the mains input at the rear of the generator ...

Page 10: ...rators internal voltmeter This will measure and display the mains voltage that is being supplied to the generator Note the displayed voltage If the voltage is 219V or less we would highly recommend fitting a t ansformer This can be ordered directly from Peak 06 3200 Dual Tap Transformer 200 230V ...

Page 11: ...Page 11 14 13 Switch the generator OFF using the switch on the front panel Remove the mains cable completely from the power supply CAUTION ...

Page 12: ...Page 12 16 15 Re attach both side panels to the generator ensuring the earth leads are re connected and the locks are secured The mains power supply can now be re connected CAUTION ...

Page 13: ...Page 13 18 17 Again Switch the generator power ON using the switch on the front panel Leave the generator switched on for a period of 30 minutes to purge the system 30 minutes ...

Page 14: ...the generator can be turned OFF Allow the stored gas in the internal tanks to dissipate The purge is now complete Once the pressure gauges on the front of the generator read 0 the silencer fittings can be emoved from the Nitrogen and Air ports ...

Page 15: ...ression Fittings 02 4421 and connect to the NITROGEN and AIR ports 02 4421 Attach the PTFE tubing 00 1266 to the fittings ttached to the NITROGEN and AIR ports and connect to the corresponding gas inlets of your instrument 00 1266 ...

Page 16: ...Page 16 24 23 Switch the generator power ON using the switch on the front panel The pressure gauges will again gradually increase to the factory set pressures ...

Page 17: ...Page 17 25 CONGRATULATIONS Your Peak Scientifi gas generator is now fully installed operational and ready to supply gas on demand to your instrument ...

Page 18: ...tor is to be installed further away from the instrument then attention needs to be paid to pressure drops that could occur The maximum distance away from the instrument the generator can be placed still using 6mm 4mm internal diameter or 3 16 internal diameter tubing is 10m For further information relating to tubing lengths please refer to the user manual Please familiarise yourself with the full ...

Page 19: ...or generators that remain unregistered after 1 month from the shipment date the warranty will be considered active from the date of factory dispatch Complete Plan only Page 19 Go Online or Complete and Return We know that registering any of your recently purchased products is not the fir t thing on your mind but it is very important to both of us Not all warranties are alike and Peak Scientific ta...

Page 20: ... Genius1025 Installation Guide Rev 3 RSID 2858 EN 10 12 19 Peak Scientific has highly t ained fully certified Field Servi e Engineers located in over 20 countries across every continent around the world This allows us to provide an industry leading rapid response service to our customers With Peak Protected your laboratory s productivity becomes our top priority To discuss Peak Protected generator...