PDQ 7101 Instruction Sheet Download Page 2

FOOT

ARM SCREW 

OR BOLT

MAIN ARM

SPINDLE

ADJUSTMENT

ARM

PRELOAD 

TO 90°

FOOT

CLOSER 

BODY

CLOSER 

BODY

FRAME/STOP 

FACE

90°

DOOR

LH

RH

CLOSED

BACKCHECK 

POSITIONING

PREPARE DOOR AND FRAME:
1.   Maximum opening = 120°

2.   Determine door hand.

3.   Align & attach full size template 

      (see reverse side).
4.   Mark door & frame with center
      punch.

5.   Remove template before 

      machining door & frame.

ADVANCE BACKCHECK:

1.   For high abuse applications.

2.   Backcheck starts 15° to 20° 

      earlier (50°/55° start).

3.   Completely close backcheck 

      positioning valve to engage advance backcheck.
      Leave valve "as is" for normal BC (70° start).
4.   If this function is desired, close valve before installing closer.

BACK OF CLOSER

             

DOOR WIDTH  

          

     

  

SIZE    INTERIOR         EXTERIOR      360° TURNS

  

 BF

 5 LBF ON 36"

     --            -15 (CCW)

  1

   32" [812.8]        28" [711.2]

   -12 (CCW)

  2

   36" [914.4]        32" [812.8]

   -7 (CCW)

  3

  42" [1066.8]       36" [914.4]

  0 (PRESET)

  4

  48" [1219.2]      42" [1066.8]    +4 (CW)

  5

  54" [1371.6]      48" [1219.2]    +6 (CW)

  6

  58" [1473.2]      54" [1371.6]    +9 (CW)

SPRING POWER 

ADJUSTING NUT

HEX 
KEY

SWEEP SPEED 

DELAYED 

ACTION

BACKCHECK

LATCH SPEED

FRONT OF CLOSER

COVER

PERFORATED 

TABS

INSTALL COVER:
1.   Remove correct tab so cover 

      slides over spindle.

2.   Install cover over closer.
3.   Secure with screws provided.

CW

CCW

(-)

(+)

LH

RH

NUT DOWN

NUT UP

ARM

ARM

OPTIONAL HOLD OPEN ARM:
Important: DO NOT use arm as limiting
stop, separate dead stop is required. 

Friction HO arm is not recommended 

for doors frequently operated in/out 

of hold open

1.   Install hold-open foot/nut.

           Left Hand (LH) door = Nut points up.
           Right Hand (RH) door = Nut points down.

2.   Loosen HO nut.
3.   Open door several degrees before HO position.
4.   Tighten nut.

7101 DOOR CLOSER INSTRUCTION SHEET

TOP JAMB INSTALLATION - PUSH SIDE - NON-HOLD OPEN AND HOLD OPEN APPLICATIONS - 120° MAX

INSTRUCTION: 719352
REV. 3             09-06-19

ADJUST SPRING POWER:

1.  Use 4 mm hex key provided to adjust to size on chart.

     Clockwise (CW) turns increase spring power (+).
     Counter-clockwise (CCW) turns decrease spring power (-).

7100 Series closers can be adjusted to meet 

ADA Barrier Free (BF) applications.  Compliance with ADA/BF 

requirements may result with door not fully closing and latching.  
Check with local AHJ.  Closer size may vary due to site conditions.

7

1.   Confirm this sheet is correct for your product and application.

2.   Read the complete instruction sheet before starting installation.
3.   Incorrectly installed or adjusted door closers can cause 

      personal injury or property damage.
4.   To ensure safe operation, closers should be examined 
      and serviced regularly.

TOOLS REQUIRED:

1.   Power drill

2.   10mm box/combo wrench
3.   Phillips screw driver
4.   #7 or 13/64" drill bit and 

      1/4-20 tap (machine screws)

5.   Tap handle
6.   5/32" drill bit (wood screws)
7.   3/8" drill bit (sex nuts)
8.   Center punch

1.   See reverse side of this sheet to machine door & frame.

2.   Dimensions based on 4-1/2" x 4-1/2" full mortise butt hinges

      with 5/8" stop and 1/8" door gap. 

3.   Confirm door & frame are properly reinforced.
4.   Sex nuts required for un-reinforced or composite fire doors.
5.   Do not install closer on the exterior (weather) side of building.

1

2

3

4

  

INSTALL CLOSER AND ARM:
1.  Attach closer body to frame.             

     Tube points toward hinges.
2. Attach foot to door.

6

  

3.  Secure main arm to closer spindle 90° to door/frame.
4.  Connect adjustment arm with foot assembly: 

     Rotate main arm until adjustment arm is 90° to door & frame. 
     Tighten arm screw or bolt .

SLOWER

FASTER

INCREASE

DECREASE

1.  Use hex key provided.

2.  Adjust SWEEP (closing max.°- 10°).
3.  Adjust LATCH (closing 10°- 0°).
4.  Adjust BACKCHECK resistance (opening 70°- max.°).  
               DO NOT COMPLETELY CLOSE VALVE
5.  Adjust (optional) DELAYED ACTION (closing max.°- 70°);
     Provides additional hesitation for access (ADA/BF) through door.

CONTROL ADJUSTMENTS: 
Closing time of 3-7 seconds is typical.  
More time may be needed for ADA/BF access.

     Clockwise (CW) = SLOWER.
     Counter-clockwise (CCW) = FASTER.
          DO NOT REMOVE VALVES

CLOSING CYCLE

Y

A

L

E

D

E

E

W

S

P

H

C

T

A

L

MAX.°

K

C

A

B

C

E

H

C

K

N

E

P

O

IN

G

OPENING CYCLE

MAX.°

8

9

10

PDQ Manufacturing

2230 Embassy Dr.

Lancaster, PA 17603

833-273-7832

833-2 PDQTECH

www.pdqlocks.com

5

P D

Q M

anu

fa

ctu

rin

g

27

54

 C

re

ek 

Hill

 R

d.

Leo

la

, P

A 1

75

40

80

0-4

41-

96

92

Fa

x: 

717

-6

56

-6

89

2

ww

w.p

dq

lo

ck

s.c

om

PA

GE

 1

 O

F 2

NO

N-H

OL

D O

PE

N A

ND

 H

OL

D O

PE

N A

PP

LIC

AT

IO

NS

71

01

 D

OO

R C

LO

SE

R M

OD

EL

S I

NS

TR

UC

TIO

N S

HE

ET

TO

P J

AM

B I

NS

TA

LL

AT

IO

N -

 P

US

H S

ID

E (

FL

US

H H

EA

DE

R O

R S

IN

GL

E R

AB

BE

T F

RA

ME

)

   

TE

MP

LA

TE

: 7

19

35

2,

RE

V. 

0  

   

   

 1

0-2

4-1

6

CL

OS

ER

 B

OD

Y

(L

EF

T H

AN

D D

OO

R)

CLOSER BODY

(RIGHT HAND DOOR)

FO

OT

(L

H)

FOOT

(RH)

H

IN

G

E

 C

E

N

T

E

R

L

IN

E

AL

IG

N W

IT

H B

OT

TO

M O

F S

TO

P

ALIGN WITH BOTTOM OF STOP

THIS SIDE UP

FOR RH DOOR

TH

IS

 S

ID

E U

P

FO

R L

H D

OO

R

A

L

IG

N

 W
IT

H

Reviews: