1
6300/6400V/VF EXIT INSTALLATION INSTRUCTION
SVR DEVICE
Phone: 833-2-PDQTEC | www.pdqlocks.com
2. SIZE DEVICE
Standard lengths are for 36" or 48" door.
Device must be cut for other lengths.
Mark length with tape – length equals
desired door size subtracted from device
size (for 30" door = cut 6" off 36" device)
ensuring a square cut.
639401 Rev1 – 5/5/21
1. PREPARE DOOR
Prepare door, frame and floor or
threshold according to template.
Refer to trim template if installing trim.
3. INSTALL DEVICE
Install device and trim with chassis/case
screws (2 or 4 screws depending on
device and trim type).
Device can be surface mounted to the
door, optional sex nuts are available,
device is through bolted if using trim.
VF devices must be through bolted on
wood or composite doors.
Panic Fire Alarm MLR
36" Device
6"
8"
2"
3"
48" Device 12"
14"
8"
9"
Maximum cut off length:
Reinforced Steel
or Aluminum Door
Surface Mount: Drill/Tap push side for 1/4-20
Solid Wood Door Drill 1/8" Pilot Hole for #10 Wood Screw
All Others
Use optional Sex Bolts. Drill push side with
9/32" drill bit. Drill pull side with 3/8" drill bit.
Mounting Options: