![PDL Thermosafe 4HS1200WH Installation Manual Download Page 3](http://html.mh-extra.com/html/pdl/thermosafe-4hs1200wh/thermosafe-4hs1200wh_installation-manual_1516733003.webp)
5. CONNECTING THE FAN
All PDL Thermosafe Ceiling Sweep Fans are pre-wired to allow for a
light to be fitted onto the fan.
If you are not fitting a light to the fan, please disregard the light
wires. The wires are connected to the incoming wiring as illustrated
in the below diagram.
6. CONNECTING THE SPEED CONTROLLER
All PDL Thermosafe Ceiling Sweep Fans come complete with a Three
Speed Flush Fitting Capacitor Controller.
This controller fits to standard 84mm fixing centres the same as a
normal switch or power point.
Although supplied standard in the vertical format, the mechanism
can be rotated through 90 degrees to provide a horizontal format if
required.
Three is the highest speed, one is the lowest.
•
Remove switch surround.
•
Terminate cables as illustrated in the below diagram .
Active to Common (C) and Switched Active terminal 3.
•
Fix controller to wallbox or bracket using screws provided.
•
Replace switch surround.
3
7. CONNECTIING THE SPEED
CONTROLLER WITH A LIGHT SWITCH
Requires additional components (not supplied with this fan)
including:
-
PDL 681M20 Switch Mechanism
-
2 Gang Grid Plate & Cover (682VH)
Fan Only
Fan with Light
CLEANING INSTRUCTIONS
To clean the fan, wipe over with a damp, soap cloth.
Do not use scourers or abrasive cleaners.
ROTARY SWITCH
MECHANISM
PDL 681M20
SWITCH
MECHANISM
ACTIVE
A
SWITCHED ACTIVE (LIGHT)
NEUTRAL
N
SWITCHED
ACTIVE
M
Red
Blue
2
1
3
0
NEUTRAL
N
SWITCHED
ACTIVE
M
Black
ACTIVE
A
ACTIVE
A
NEUTRAL
N
SWITCHED
ACTIVE
2
1
3
Red Blue Black
C
M
8. CHECK FORWARD / REVERSIBLE SWITCH
The forward / reversible switch is located on the bottom cowl.
Check switch and make sure it is in correct setting, depend on
summer or winter season.
Note that the forward / reversible switch must be fully engaged for
the fan to operate.
SUMMER
WINTER