background image

 

 

 

 

MODEL:

  

med

TAB

19D/

 

med

TAB

16D

 

/

 

med

TAB

14D

 

Document Number:

 

PD196-434R1 

 

User Manual 

 medTAB

®

 with GENiO

 

Page 6 of 21 

 

 

PDi Communication Systems, Inc. 

 40 Greenwood Ln 

 Springboro, Ohio 45066 USA 

 

www.pdiarm.com

 an

www.mymedTV.com

 

 Phone 800.628.9870 

 

 

INTRODUCTION 

The med

TAB

® 

model-D includes cloud-based GENiO

 remote content management software. medTAB can deliver a custom patient 

TV experience with your brand logo, weblinks to your patient education videos, daily menus, video call software, patient surveys, 

and more. This affordable solution is easy to manage with NO ADT integration. This complete, customizable, personal patient 
television system by PDi delivers a touchscreen experience that patients understand and enjoy as soon as they touch it.  Contact 
PDi for more information on using GENiO to create a customized user interface with your weblinks or custom applications. 
 
Not ready to customize? medTAB is simple and scalable out-of-the-box. Choose to setup TV with internet or offer patients 
expanded entertainment with built-in tv, games and relaxation apps, no internet required. When connected to the internet via WIFI 
or Ethernet, without customization, patients also enjoy access to a web browser, social sites, and a direct link to health news at 
cdc.gov.  
 

INSTALLING THE TELEVISION 

Installation Precautions 

For models powered over coax, use only a power source from PDi suitable for use in a healthcare facility. The single coaxial cable 
on top of the TV is used to supply both low voltage AC or DC power (28VAC or 24VDC) and RF signal to the television. 
 
For models powered by ethernet (PoE) use only UL listed power sourcing equipment that offers 60W per port using all 4 pairs for 
power delivery. This is sometimes called 

UPoE

PoE++

 or 

802.3bt type 3

. PDi recommends the 

Microchip Microsemi PD-9506G/ACDC/M 

midspan power inserter. The ethernet cable on top of the TV is used to supply both 

power and data. Be sure power is not applied to the coaxial cable entering the TV. 

Coax Cable Specifications 

When using a central power supply, cable selection is crucial. Due to long coax cable runs encountered in hospital installations, 
coax cable employing a solid copper center conductor and copper shield is required. Cable run lengths MUST NOT exceed 150 feet. 
Required coaxial cable numbers include Alpha M4182 (replaced Alpha 9804C) (non-plenum), Belden 9248 (non-Plenum), West 
Penn 806 (non-Plenum), or West Penn 25806 (Plenum), which have been tested with coax-powered TVs. 

Category Cable Specifications 

PoE models are IEEE 802.3bt compatible. When using a PoE power inserter to apply power to ethernet, CAT5e or better cable may 
be used.  The total cable length from network switch to PDI device may be up to the standard 330ft. 

Arm Mounting 

This television is designed to attach to a PDi suspension arm.  

 
Arm Recoil Hazard:

  The safety brake pin must remain in the SAFETY BRAKE PIN HOLE whenever the television is removed from 

the arm or when the arm is removed from the wall bracket to prevent INJURY from the arm springing open. 

Note:

  Contact PDi for 

additional information on arm compatibility and cable requirements. 

 

KEYPAD CONTROLS 

Keypad buttons vary by model as shown below. Each model has at least a HOME and BACK button. 
 

 

Summary of Contents for medTAB14D

Page 1: ...ymedTV com USER MANUAL Document Number PD196 434R1 Model Numbers medTAB14D medTAB16D medTAB19D Arm Mounted Healthcare grade Touchscreen LED Smart HDTV with Android OS and GENiO Remote Device Managemen...

Page 2: ...S 6 INITIAL SETUP 7 CHANGE USER INTERFACE 9 UNLOCK ANDROID SETTINGS MENU 10 DEVICE INTERNAL SETTINGS 10 ANDROID SETTINGS 10 Android Device Settings 11 Settings Preferences UPDATE IMAGE 12 TELEVISION S...

Page 3: ...Update 18 Signal Information 18 ADVANCED OPTIONS HDMI 18 ADVANCED OPTIONS TIME 19 Time Source 19 Date and Current Time 19 Off Time 19 Scheduled Time 19 Sleep Time 19 ADVANCED OPTIONS FEATURES 20 Auto...

Page 4: ...f the TV does not operate properly unplug it and call an authorized service center or PDi Cleaning and Disinfection Clean the exterior of this television by removing dust with a lint free cloth Spot t...

Page 5: ...nstallation instructions TV s can pose a striking hazard when mounted at an elevated level 16 Power Sources This product should be operated only from the type of power source indicated on the marking...

Page 6: ...28VAC or 24VDC and RF signal to the television For models powered by ethernet PoE use only UL listed power sourcing equipment that offers 60W per port using all 4 pairs for power delivery This is some...

Page 7: ...CONFIRM Online Internet the 6 icon image for full internet access now including cdc gov weblink for patient education You must connect to the Internet via ANDROID SETTINGS shown below before you choos...

Page 8: ...id Network Settings below The Education icon defaults to the website cdc gov for general patient education information The Social icon defaults to Facebook Instagram LinkedIn Pinterest Twitter and You...

Page 9: ...LOCK ANDROID SETTINGS For GENiO or Online Interface you will need to click thru to SETTINGS to make a network connection to enable the Internet 2 Touch the screen outside of the pop up keyboard to cle...

Page 10: ...ly for GENiO or Online Interface you will need to click thru here to SETTINGS to make a network connection to enable the Internet This screen shows two way information so once you connect to the netwo...

Page 11: ...ts to access the web and the GENiO servers The only external port used is 443 HTTPS As some websites still use port 80 HTTP PDi recommends allowing it as well 2 Settings Inputs Identify your HDMI inpu...

Page 12: ...on 2 Settings Language Default language is English US If you choose an alternate language it will change the menu and the web browser language 3 Settings Keyboard Device includes AOSP keyboard and Gbo...

Page 13: ...s menu password See pg 10 for default password then touch the blue checkmark on the touchscreen or press OK on remote From the onscreen user interface press Settings on the TV app user controls or pre...

Page 14: ...ect Channel Setup 3 Select Customize channel list 4 Scroll thru the channel list and uncheck any channels you want to exclude from the channel list 5 Touch BACK or press LAST on TV remote to exit sett...

Page 15: ...lence Scenes US Ratings TV Y Young Children Content designed to be appropriate for all children TV Y7 Children 7 and over Considered suitable for children age 7 and above TV G General Audience Conside...

Page 16: ...ng applies to all TV and Android screens Picture Mode includes 8 automated options to adjust the picture quality Dynamic Standard Soft User Game Vivid Natural and Sports Picture Mode The picture setti...

Page 17: ...mum volume level the unit can reach Setting this to any value other than 0 guarantees that some level of sound will always be heard when the TV is operating Touch the sliding scale to adjust volume fr...

Page 18: ...to another service level ie Free copied to Basic Power on Channel Power on Channel will display a certain channel each time the TV is turned on This feature is useful for hospitals that have a Welcome...

Page 19: ...ord See pg 10 for default password 2 Select Advanced Option 3 Select Time Time Source You may choose to use network provided time or DTV time source Date and Current Time Displays current date and Cur...

Page 20: ...he TV from being turned off by the TV power button or the remote control Bed A B C D The TV can be controlled by a patient IR remote The TV offers selectable codes Bed A Bed B Bed C and Bed D for inde...

Page 21: ...e into the cloning port and open USB Cloning The USB Cloning Menu will appear 3 Select Restore Setting to TV 4 Press Save Remove USB RF Cloning The difference between Auto RF cloning and Manual RF clo...

Reviews: