background image

1.

 

Touch the probe tip to the hot conductor or insert into 

the hot side of the electrical outlet. 

2.

 

If AC voltage is present, a red detector LED will 

illuminate. 

NOTE

: The conductors in electrical cord sets are often 

twisted. For best results, drag the probe tip along 

a length of the cord to assure placing the tip in 

close proximity to the live conductor.

 

NOTE

: The detector is designed with high sensitivity. 

Static electricity or other sources of energy may 

randomly trip the sensor. This is normal operation 

 

OPERATOR SAFETY   

1.

 

Do not clamp around conductors with voltages 

equal to or exceeding 600V DC or 600V rms AC. 

2.

 

To avoid physical injury, measurements on bare 

conductors or conductors with cracked or frayed 

insulator are forbidden. 

 

SPECIFICATIONS 

GENERAL   

Captured Conductor Size: 1 ¼ inch   

Low Battery Indictor: Red LED light   

Operating Temperature: 32°F to 122°F, 70% R.H. 

Storage Temperature: -4°F to 158°F, 80% R.H. 

Battery Type: Two “AAA” 1.5V Battery 

 

ELECTRICAL

 (73°±5°F, 70% R.H. maximum) 

Effective Measurement Range 

40A (output: 10mV/A): DC or rms AC for 400mV or 

600mV range of the multimeter. 

400A (output: 1mV/A): DC or rms AC for 400mV or 

600mV range of the multimeter. 

 

Accuracy 

 

Current Clamp Accuracy: 

DCA range: 40A 

0~40.0ADC:         ± (2.5% +0.1A) 

 

DC range :400A 

0~400ADC:         ± (2.8% +0.5A) 

 

ACA range: 40A

(50/60Hz) 

0~40.0AAC:         ± (2.5% +0.1A) 

 

ACA range: 400A

(50/60Hz) 

0~400AAC:         ± (2.8% +0.5A) 

 

WARRANTY 

This PDI product is warrantied to be free from defects 

in materials and workmanship for a period of two (2) 

years  from the verified date of purchase. During the 

two  year warranty period, PDI will either repair or 

replace the defective unit, at PDI’s discretion. A 

purchase receipt or other acceptable form of proof of 

original purchase date will be required before any 

warranty processes begin. PDI warrants all authorized 

repairs with a six (6) month limited warranty.    View 

full warranty details and register your PDI product at 

www.PDImeters.com

   

 

NOTE: Online product registration is required for 

all warranty claims.   

 

 

SAFETY INFORMATION 

The instrument complies with class II, overvoltage 

CAT III  -  600V of the EN 61010-1, and EN 

61010-2-032  standards. Pollution degree 2 in 

accordance with IEC 664 indoor use. If the equipment 

is used in a manner not specified, the protection 

provided by the equipment may be impaired. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 