Wiring Guidelines—Op onal for TruSwim Propulsion System (60 Hz) North America
29
Your new TruSwim Swim Spa will arrive from the factory wired to operate with a single 120/240 volt 50 Amp Ground Fault
Circuit Interrupter Type A circuit breaker (not included from PDC) supplied from the homeowner’s power source.
The system, when wired this way, is designed to turn o
ff
the high speed of the jet pump and heater while the TruSwim
propulsion system is opera ng. Since water cools slowly, this is adequate for most installa ons.
If you choose, the swim spa can be wired with an addi onal 240 volt 30 amp Ground Fault Circuit Interrupter (not supplied)
power source from the home owners electrical power. The addi on of the 30 amp circuit will allow the high speed of the jet
pump and the heater to operate simultaneously with the TruSwim propulsion system a er a programming change is made to
the opera ng system of the swim spa. This programming change is not supplied with this manual due to the possibility of
other features being changed accidentally. Your swim spa retailer should have the informa on needed to make the necessary
programming change. In the event he does not or no retailer is available contact our customer service for assistance.
Steps
for
Adding
Addi onal
Power
Supply
1. Make sure all electrical power is turned o
ff
before performing service.
2. Disconnect and remove wire #1 from both the relay center and spa control center. See
fi
gure #1 and
fi
gure #2.
3. Install the 30 amp 240 volt ground fault circuit protected L1 and L2 legs into the fuse block and the ground wire in the
ground strip where the wire was removed from the relay control center as shown in
fi
gure #3.
4. Place a cap into the hole le behind from the removal of wire #1 in the spa control center.
5.
FOLLOW
ALL
OTHER
START
UP
PROCEDURES
WITHIN
THIS
MANUAL.
FOR
QUALIFIED
ELECTRICIAN
REFERENCE
ONLY!
All
installa ons
and
connec ons
are
to
be
performed
by
a
quali
fi
ed,
licensed
electrician
only
and
in
accordance
with
the
Na onal
electric
code
and
all
applicable
local
regula ons.
Ensure
power
is
turned
o
ff
prior
to
making
any
electrical
connec ons.
FIGURE
#1
Remove wire #1
Remove Strain
Relief and cap
remaining hole
Remove wire #1
FIGURE
#2
FIGURE
#3
L1, L2, &
ground wire
connec on
30 amp 240 volt
ground fault
circuit
protected feed