22
NCV Test
1. Press the
button to turn on the device, press the
button
and choose the
function. The display will show “NCV”.
2. Gradually approach the voltage source with the NCV probe,
which sits at the top of the device.
3. When the meter senses weak AC signals, the indicator lights
up green, while the buzzer sends out slow-paced acoustic
signals. The display will show "--- L".
4. When the meter senses strong AC signals, the indicator lights
up red, while the buzzer sends out fast-paced acoustic signals.
The display will show "--- H".
WARNING:
•
Do not measure voltage above 600V; otherwise the
instrument might get damaged.
•
Remove all probes from the input sockets.
•
Pay special attention to safety when measuring high
voltage to avoid electric shock or personal injury.
•
The NCV test is only a first indication and cannot replace
voltage measuring.