PCI SWP-0412G2 Series User Manual Download Page 1

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

  

   

Summary of Contents for SWP-0412G2 Series

Page 1: ......

Page 2: ...INSTALLATION 7 RACK INSTALLATION 7 INSTALLING NETWORK CABLES 7 DESCRIPTION OF SWITCH FUNCTIONS 8 JUMBO FRAME 8 FLOW CONTROL AND BACKPRESSURE 8 MIRROR 8 VLAN 8 TRUNK AGGREGATION 8 QUALITY OF SERVICE Q...

Page 3: ...MMAND LINE INTERFACE 28 START UP AND TERMINAL CONFIGURATION 28 LOGIN LOGOUT PROCEDURES 28 COMMAND HIERARCHY 29 ENTERING COMMANDS 29 COMMAND DESCRIPTION 30 System Commands 30 Console Commands 31 Port C...

Page 4: ...rt automatically disables its corresponding copper port The management functions enable efficient network usage VLAN reduces the collisions caused by broadcasting Port Aggregation enlarges the bandwid...

Page 5: ...ansmitting receiving 1000M Off No valid link on this port or the Port is connected at 10 100 Mbps Steady Green A valid link is established and there is no data transmitting receiving Blinking Green A...

Page 6: ...the copper port Restore Default Button You can use this button to reset the switch or restore it to its factory default settings To reset the switch press the button once To restore factory default s...

Page 7: ...ect all cables from the Switch before mounting it 2 Place the unit the right way up on a hard flat surface with the front facing you 3 Locate a mounting bracket over the mounting holes on one side of...

Page 8: ...s and hence is able to monitor the traffic through the specified port VLAN This Switch supports Virtual LAN which means the network can be segmented into groups to reduce collisions caused by wide bro...

Page 9: ...5200 baud 2 Data format 8 data bits 1 stop bit and no parity 3 Flow control none 4 Click the property icon select settings make sure that The Function arrow and ctrl keys act as Terminal keys Emulatio...

Page 10: ...mart Switch User Guide Homepage After successful log in the SYSTEM Configuration page appears this is also the Homepage You can click on the hyperlinks on the left side of each page to get access to e...

Page 11: ...is device S W Version The software version of this device IP Address Set up the IP address of the switch Subnet Mask Set up the Subnet Mask of the switch Gateway Set up the Gateway of the switch Manag...

Page 12: ...of each port and allows users to configure speed flow control and maximum frame size for each port Items Functions Link Shows the link status of each port The column lights green and shows the link sp...

Page 13: ...Max Frame length Adjust the size of Jumbo Frames The default is 1518 bytes The Maximum value can be up to 9k bytes To save the configuration of the system click Apply You can also click the Refresh bu...

Page 14: ...ructions to configure To add new VLAN groups 1 Fill in a VLAN ID from 2 to 4094 in the VLAN Port column 2 Select the ports for each VLAN group 3 Click the Apply button to execute To delete a VLAN grou...

Page 15: ...lect untagged to cancel For example if an Egress tagged port receives an untagged frame it will be transmitted as a PVID tagged frame For the detail tagging status please refer to the following table...

Page 16: ...to save the settings There are three aggregation modes for you to set up SMAC DMAC and XOR SMAC mode selects the path of packets according to Source MAC while DMAC mode selects path according to Desti...

Page 17: ...2 Series L2 Web Smart Switch User Guide Quality of Service QoS enhances communication quality by giving precedence to certain classes of packets This switch provides port based tag based and DSCP QoS...

Page 18: ...high or low priority To assign a priority level to each port 1 Select Port in the Mode column for those ports that are going to function as part of port based QoS Click the Apply button 2 Click the Po...

Page 19: ...Tagged in the Mode column for those ports that are going to perform tag based QoS Click the Apply button 2 Click the Tag priority button The Tag Priority Setting page shows up 3 Select the port that...

Page 20: ...it 1 Throughput Bit 3 Reliability 0 Normal 0 Normal 0 Normal 1 Low 1 High 1 High Note The Switch distinguishes packets with DSCP precedence 000 routine only To configure DSCP based QoS configuration 1...

Page 21: ...It allows administrators to analyze and monitor the traffic of the monitored ports Mirror Configuration 1 Select those ports that are going to be monitored by marking the checkboxes in the Monitor Po...

Page 22: ...ws users to limit the bandwidth for each port and configure the rules for Storm Control which limits the flow of broadcast and multicast To perform storm control 1 Click on each drop list to specify a...

Page 23: ...ged via SNMP 1 Select enable in the drop menu 2 Specify a trap IP A trap IP is the destination port for sending trap information which is usually the IP address of network administrators 3 Fill in a n...

Page 24: ...tool lists a maximum of 16 devices respectively for auto and manual modes Auto Search 1 Click the Apply button to start 2 The devices being found are listed below 3 Click the IP address hyperlink to g...

Page 25: ...k the Clear button to clean all statistics or click the Refresh button to renew the statistics Detailed Statistics The Detailed Statistics is provided for users to see the detailed transmitting and re...

Page 26: ...restore the factory default settings click the Yes button Note The IP address of the device will also be reconfigured to the factory default setting which is 192 168 1 254 Smart Boot This Smart Boot...

Page 27: ...button 2 Locate the firmware file 3 Click the Upload button to execute Note This new firmware is going to be applied on the remaining flash that you have NOT selected in Smart Boot that is the new fi...

Page 28: ...following configuration 1 Data rate 115200 baud 2 Data format 8 data bits 1 stop bit and no parity 3 Flow control none 4 Click the property icon select settings make sure that The Function arrow and...

Page 29: ...s or help to get help The help depends on the context where you are in the program At top level a list of command groups will be shown At group level a list of the command syntaxes will be shown If gi...

Page 30: ...stem Reboot System Configuration all Syntax System Configuration all Description Show system name username password software version and management MAC address Optionally show the full configuration a...

Page 31: ...imeout timeout Console Prompt prompt string Console Configuration Description Show configured console prompt and timeout Console Timeout timeout Description Set or show the console inactivity timeout...

Page 32: ...rol mode and admin state for the port portlist Port list Default All ports Port Mode portlist mode Description Set or show the speed and duplex mode for the port portlist Port list Default All ports m...

Page 33: ...maximum frame size in bytes including FCS for frames received on the port Tagged frames are allowed to be 4 bytes longer than the maximum frame size Use the reset option to return to default setting...

Page 34: ...st Description Show the VLAN egress mode port VLAN ID and accepted frame type for the port and the permanently stored VLAN table portlist Port list default All ports VLAN Add vidlist portlist Descript...

Page 35: ...ss tag setting VLAN PVID portlist vid none Description Set or show the port VLAN ID Untagged frames received on the port will be classified to this VLAN ID Frames classified to this VLAN ID will be se...

Page 36: ...aggregation mode Aggr Delete portlist Description Delete link aggregation group portlist Port list Aggregations including any of the ports will be deleted Aggr Lookup portlist Description Look up and...

Page 37: ...efault All ports tag port diffserv Enable tag port or IP differentiated services class of service for the port default Show mode QoS Port portlist class Description Set or show the port class In tag m...

Page 38: ...r Source portlist enable disable Mirror Configuration Description Show the mirror destination port and mirror mode for source ports Mirror Port port Description Set or show the mirror destination port...

Page 39: ...n Activate or deactivate the Web management enable disable Enable disable Web management default Show Web management SNMP Commands Commands at SNMP level SNMP Configuration SNMP Community get set comm...

Page 40: ...t s 128 256 512 1024 2048 3072K default Show rate Ratelimit Configuration Description Show the Ratelimit setting Ratelimit Setup traffic type option Description Set or show the ratelimit configuration...

Page 41: ...e or disable egress rate Disable or set leaky bucket rate in Kbit s 128 256 512 1024 2048 3072k default Show egress rate Ratelimit Ingress portlist enable disable rate Description Set or show the ingr...

Page 42: ...s System Power RJ 45 Port 1000M 10 100M Memory 8K MAC entries 340K Buffer Memory 9K Byte Jumbo Frame Emission FCC Class A CE VCCI RoHS Operating Temperature 0 0 40 0 C 32 0 104 0 F Operating Humidity...

Reviews: