background image

 

 

 

 

Manual 

 

Version 1.0 

Date of creation: 31.05.2016 

Date of last change: 28.11.2017

 

 

 

CO2 Analyser

 PCE-WMM 50 

PCE Americas Inc.

711 Commerce Way 

Suite 8 

Jupiter

FL-33458

USA

From outside US: +1

Tel: (561) 320-9162

Fax: (561) 320-9176

[email protected]

www.pce-instruments.com/english

www.pce-instruments.com

PCE Instruments UK Ltd.

Units 12/13 

Southpoint Business Park 

Ensign way

Hampshire / Southampton

United Kingdom, SO31 4RF

From outside UK: +44

Tel: (0) 2380 98703 0

Fax: (0) 2380 98703 9

    [email protected]

Summary of Contents for PCE-WMM 50

Page 1: ...iter FL 33458 USA From outside US 1 Tel 561 320 9162 Fax 561 320 9176 info pce americas com www pce instruments com english www pce instruments com PCE Instruments UK Ltd Units 12 13 Southpoint Busine...

Page 2: ...n 6 3 1 Device 6 3 2 Display 9 4 Getting started 10 4 1 Preparation 10 4 2 Power connection 11 5 Operation 12 5 1 Further measuring functions 12 5 2 Settings 13 6 Maintenance 14 6 1 Repair cleaning an...

Page 3: ...tightly with the elastic plug lock so that it can only be removed using mechanical tools If you wish to connect a fan to the potential free contacts of the sensor unit make sure that the fan has its o...

Page 4: ...250 V AC max 2 A Alarm thresholds Alarm 1 0 5 1 1 5 2 Alarm 2 1 5 2 2 5 3 3 5 4 Menu items Function test of connection between sensor unit and remote display unit calibration switching between C and F...

Page 5: ...nal digital display to measure temperature in C and F LEDs for operation alarms 1 2 and monitoring of voltage supply Display elements Function test Reset menu selection Enter shifting between C and F...

Page 6: ...tential free contact which can for instance activate a fan which reduces the increased CO2 concentration in the room concerned Sensor unit A LC display B Yellow LED error indication C Red LED 2 AL2 D...

Page 7: ...between sensor unit and remote display unit CAL Calibration of gas detector ReFactSet Reset to factory default settings You can set two alarm thresholds AL1 AL2 1 Alarm threshold Selectable threshold...

Page 8: ...te display unit O Green LED power supply P Red LED 1 AL1 Q Red LED 2 AL2 R Yellow LED error indication S LC display T Enter key U Mode key V RJ45 connection Output W RJ45 connection for sensor unit In...

Page 9: ...d LED 1 flashes the buzzer sounds and the potential free contact closes if the red and blue cables are connected or closes if the white and blue cables are connected Second alarm threshold If the CO2...

Page 10: ...2 concentration before entering the room where the sensor unit is located The connection between both devices can be checked by using the DIAG function which is described in the further course of this...

Page 11: ...blue cables are connected the contact closes B blue cable R red cable W white cable 1 power connection fan 2 fan 4 2 Power connection Connect the mains adaptor to the wall socket Attach the elastic sa...

Page 12: ...larms are triggered early 5 1 Further measuring functions DIAG function The communication between the sensor unit and the remote display unit should be checked on a regular basis by using the DIAG fun...

Page 13: ...actory default settings are restored after the confirmation 5 2 Settings Lock unlock The gas detector has an automatic lock function to prevent the settings from being changed unintentionally If you w...

Page 14: ...e key The following options are available 1 5 2 2 5 3 3 5 4 Select the desired option and press the Enter key to confirm 6 Maintenance 6 1 Repair cleaning and maintenance Repairing Do not try to repai...

Page 15: ...ubber cap on the gas input M to prevent water from getting into the device Maintenance The communication between the sensor unit and the remote display unit should be checked on a regular basis by usi...

Page 16: ...f this does not help please contact our customer support Er7 Internal data transfer error Er7 flashing LED FLT flashing buzzer makes noise Er7 flashing LED FLT flashing buzzer makes noise Unplug the p...

Page 17: ...use them or give them to a recycling company which disposes of the devices in line with law If you have any questions please contact PCE Instruments 9 Contact If you have any questions about our rang...