background image

11. ADVANCED SETTING

press the " FUNCTION (SET) Button " ( 3-6, Fig. 1 ) continuously at 
least Five seconds will enter the " Advanced  Setting " mode. then 
press the " FUNCTION (SET) Button " ( 3-6, Fig. 1 ) once a while in sequence 
to select the two main function, the display will show :

POFF.......

Auto power OFF management

t-CF.......

Select the Temp. unit to 

 or 

Remark: 
wait eight seconds or short press " power button " to back measurement.

11-1 Auto power OFF management

When the lower display show " POFF " 

1) Use the " 

 button  " ( 3-3, Fig. 1 ) or  " 

 button " ( 3-5,Fig. 1 "

to select the upper text to " yES " or " no ".

yES - Auto Power Off management will enable.
no - Auto Power Off management will disable.

2) After select the text to " yES " or " no ",  press the

" REC(Enter) Button " ( 3-4, Fig.1 ) will  save the setting
function with default.

11-2 Select the Temp. unit to 

 or 

When the lower display show " t-CF " 

1) Use the  " 

 button  " ( 3-3, Fig. 1 ) or  " 

 button " ( 3-5,Fig. 1 "

to select the upper Display text to " C " or " F ".

C - Temperature unit is 

F - Temperature unit is 

2) After Display unit is selected to " C " or " F ",  press the

" REC(Enter) Button " ( 3-4, Fig.1 )  will  save the setting
function with default.

13

Summary of Contents for PCE-T 260

Page 1: ...es are developed Please read the following instructions carefully and always keep this manual within easy reach OPERATION MANUAL PCE Americas Inc 711 Commerce Way Suite 8 Jupiter FL 33458 USA From out...

Page 2: ...minal 6 3 13 IR Thermometer 6 3 14 Battery Compartment Cover 6 3 15 Reflecting Mark 6 3 16 Photo led light beam 6 3 17 Stroboscope flash light red indicator 6 3 18 Monitor indicator 6 3 19 DC 9V adapt...

Page 3: ...alue max value min value will be stored into the memory automatically can be obtained by pressing REC Button Large LCD display High visible LCD display gives RPM reading exactly with no guessing or er...

Page 4: ...Over Input Indication of Indicater Power Supply UM3 AA X 4 DC 6 V battery DC Adapter adapter is optional Power Approx DC 42 mA Consumption Weight 240g 0 53 LB Meter only Dimension HWD 207 x 67 x 45 m...

Page 5: ...ing RPM value is 1 800 RPM The max min detecting distance may change under different environment different reflecting tape or the measuring RPM beyond 1800 RPM Contact Tachometer Measurement Contact T...

Page 6: ...e Resolution 0 1 RPM 5 RPM 1 000 RPM 30 000 50 000 RPM 1 RPM 10 RPM 1 000 30000 RPM 50 000 99 990 RPM Function Digital rotate knob buttons x 2 button 2 button button button Accuracy 0 1 reading 2d Spe...

Page 7: ...158 0 1 2 2 reading IR thermometer Emissivity 0 95 fixed value Spectral response 6 to 14 m wavelength Field of View D S D S Approx 3 1 ratio D distance S spot Unit Range Resolution Accuracy 30 to 305...

Page 8: ...partment Cover 3 4 REC DOUBLE button 3 15 Reflecting Mark 3 5 UNIT button 3 16 Photo led light beam 3 6 Function button 3 17 Stroboscope flash light red indicator 3 7 RPM Adapter 3 18 Monitor indicato...

Page 9: ...the object being measured and align the Photo light beam 3 16 Fig 1 with the applied target Verify that the Monitor Indicator 3 18 Fig 1 lights when the target pass through the light beam Release the...

Page 10: ...ifferent kind measured rotating axis it may changed the rubber for RPM adapter from CONE type to FUNNEL type 3 9 Fig 1 5 2 Surface Speed Measurement 1 Power On the meter by short pressing the Power bu...

Page 11: ...OUBLE button then Press button once will double the display value For example the display is 100 0 Press and hold the DOUBLE button then Press button once the display will change to 200 0 Operation ag...

Page 12: ...eed Then lower the flashing rate until a single and stationary image appears this is the actual true speed 6 3 Checking Motion For motion analysis simply locate the actual speed as mentioned above and...

Page 13: ...UREMENTS 1 Power On the meter by short pressing the power button 3 2 Fig 1 1 5 seconds the LCD will light 2 Use the Function button 3 6 Fig 1 short push to select function until to the I r function be...

Page 14: ...Button 3 4 Fig 1 once the REC and MAX Symbol indicator will be light and the maximum value will appear on the display b Press the REC Button 3 4 Fig 1 again the REC and MIN Symbol indicator will be li...

Page 15: ...wer display show POFF 1 Use the button 3 3 Fig 1 or button 3 5 Fig 1 to select the upper text to yES or no yES Auto Power Off management will enable no Auto Power Off management will disable 2 After s...

Page 16: ...with DC 1 5 V battery UM3 AA Alkaline heavy duty x 4 PCs and reinstate the cover 4 Make sure the battery cover is secured after changing the battery 13 RS232 PC SERIAL INTERFACE The instrument has RS...

Page 17: ...nciator for Display ft min 11 inch min 28 m min 60 RPM 27 01 02 D10 Polarity 0 Positive 1 Negative D9 Decimal Point DP position from right to the left 0 No DP 1 1 DP 2 2 DP 3 3 DP D8 to D1 Display rea...

Reviews: