Establishing a Bluetooth connection  

To  establish  a  Bluetooth  connection,  first  switch  on  the  meter.  Then  download  the  app  "PCE 
SmartMeasure Environmental" from the respective store. 
 

 

 

Android Store 

Apple Store 

 
To establish a connection, first switch on the meter.  
Enable Bluetooth and the location function in your mobile device. 
Next, open the app and apply the "Connect" button.  
Now select "Search devices" in the lower area of the display and connect to the PCE-PMI 1BT by 
selecting the device. 
After the connection, the meter can be operated via the app. 

Note: 

Do not establish a connection via the system setting but only via the app.  

5.1 

Making a measurement 

Once  a  connection  has  been  established,  a  measurement  can  be 
taken. The meter should be held as shown in the illustration. For a 
measurement,  place  the  measuring  ball  on  the  surface  to  be 
checked. You can read the measured value directly from your mobile 
device.  
 

Note: 

On  an  even  surface,  the  distance  between  the  nearest  wall 

and  the  measuring  ball  must  not  be  less  than  10  cm.  During  the 
measurement,  the  measuring  device  must  be  positioned 
perpendicular to the sample. 
When making a measurement, your hand should not come close to 
the metal ball as the water content in the human body will falsify the 
measurement. 

Replacing batteries 

To  replace  the  batteries,  first  switch  off  the  meter.  Then  open  the 
battery compartment on the back and insert 2 x 1.5 V AAA batteries. Make sure that the polarity 
is correct.  

Status display 

Status display (LED) 

Meaning 

Green (flashing) 

Bluetooth connection established 

Yellow (flashing) 

Bluetooth connection not established 

Yellow (constant) 

Battery voltage too low 

Automatic power off 

When the meter is not connected to a mobile handheld device, it will switch off within 3 minutes.  

 

Summary of Contents for PCE-PMI 1BT

Page 1: ...Moisture Meter User Manual User manuals in various languages fran ais italiano espa ol portugu s nederlands t rk polski can be found by using our product search on www pce instruments com Last change...

Page 2: ...ty notes 1 2 Specifications 2 3 Delivery scope 2 4 Device description 3 5 Establishing a Bluetooth connection 4 5 1 Making a measurement 4 6 Replacing batteries 4 7 Status display 4 8 Automatic power...

Page 3: ...ure Do not expose the device to shocks or strong vibrations The case should only be opened by qualified PCE Instruments personnel Never use the instrument when your hands are wet You must not make any...

Page 4: ...tooth 4 0 Measuring principle capacitive electrical resistance Sensor type metal spheroid Power supply 2 x 1 5 V AAA batteries Operating conditions 0 50 C 32 122 F 90 RH non condensing Dimensions 160...

Page 5: ...PCE Instruments 3 4 Device description No Description 1 Measuring ball 2 Status display 3 On and off switch 4 Battery compartment cover 5 Closure of the battery compartment cover 6 Loop holder...

Page 6: ...n For a measurement place the measuring ball on the surface to be checked You can read the measured value directly from your mobile device Note On an even surface the distance between the nearest wall...

Page 7: ...es Due to the contained pollutants batteries must not be disposed of as household waste They must be given to collection points designed for that purpose In order to comply with the EU directive 2012...

Page 8: ...esciatina 878 B Interno 6 Halkal Merkez Mah Ensign Way Southampton 55010 Loc Gragnano Pehlivan Sok No 6 C Hampshire Capannori Lucca 34303 K k ekmece stanbul United Kingdom SO31 4RF Italia T rkiye Tel...

Reviews: