background image

 

 

©  PCE Instruments 

 

Safety notes 

Please read this manual carefully and completely before you use the device for the first time. The 
device  may  only  be  used  by  qualified  personnel  and  repaired  by  PCE  Instruments  personnel. 
Damage or injuries caused by non-observance of the manual are excluded from our liability and 
not covered by our warranty. 
 

 

The device must only be used as described in this instruction manual. If used otherwise, 
this can cause dangerous situations for the user and damage to the meter. 

 

The instrument may only be used if the environmental conditions (temperature, relative 
humidity, …) are within the ranges stated in the technical specifications. Do not expose 
the device to extreme temperatures, direct sunlight, extreme humidity or moisture. 

 

Do not expose the device to shocks or strong vibrations. 

 

The case should only be opened by qualified PCE Instruments personnel. 

 

Never use the instrument when your hands are wet. 

 

You must not make any technical changes to the device. 

 

The appliance should only be cleaned with a damp cloth. Use only pH-neutral cleaner, 
no abrasives or solvents. 

 

The device must only be used with accessories from PCE Instruments or equivalent. 

 

Before each use, inspect the case for visible damage. If any damage is visible, do not 
use the device. 

 

Do not use the instrument in explosive atmospheres. 

 

The measurement range as stated in the specifications must not be exceeded under 
any circumstances. 

 

Non-observance of the safety notes can cause damage to the device and injuries to 
the user. 

 

Do not touch the lenses. 

 

When the microscope is not in use, use the dust cover. 

 
We do not assume liability for printing errors or any other mistakes in this manual. 
 
We expressly point to our general guarantee terms which can be found in our general terms of 
business. 

Delivery scope 

1 x digital microscope PCE-LCM 50 
1 x USB mouse 
1 x micro-SD card 
1 x protective cover 
1 x contrast disc black / white 
1 x translucent lens 
1 x mains adaptor 
1 x protective film 
1 x user manual 
 
 
 

 

Summary of Contents for PCE-LCM 50

Page 1: ...ital microscope User manuals in various languages fran ais italiano espa ol portugu s nederlands t rk polski can be found by using our product search on www pce instruments com Last change 26 Septembe...

Page 2: ...s 1 Safety notes 1 2 Delivery scope 1 3 Specifications 2 4 Device description 3 5 Lighting 3 6 Description of user interfaces 4 6 1 Menu screen left 4 6 2 Menu at the bottom 11 7 Troubleshooting 13 8...

Page 3: ...instrument when your hands are wet You must not make any technical changes to the device The appliance should only be cleaned with a damp cloth Use only pH neutral cleaner no abrasives or solvents Th...

Page 4: ...x 600 pixels Frame rate 30 fps Pixel size 2 75 x 2 75 m Signal to noise ratio 65 db Interface USB 2 0 Power supply mains adaptor primary 100 240 V secondary 12 V 1 A Illumination incident light ring...

Page 5: ...back 8 Display on off switch 9 Illumination for transmitted light microscopy 10 Stage 11 LED ring 12 Mechanically adjustable zoom 5 Lighting The microscope has an incident and a transmitted light func...

Page 6: ...op a video recording After the recording has started a time indication starts in the upper right corner of the display indicating the recording time File overview Shows the existing image and video fi...

Page 7: ...and the large view Delete button Delete the displayed item In the file overview an entry must be selected by a mouse click 6 1 2 Drawing menu Note Some characters are placed to indicate distances or...

Page 8: ...circle using the circle from radius function Here you can create one or more circles with the same centre point Distance between line and circle Create a circle using the circle from radius function...

Page 9: ...Subsequently another reference point is used to create a line that is perpendicular to the first line Parallel lines First a line is created Then with another click you create the first reference poin...

Page 10: ...ions of the drawing elements as a CSV file This file is saved to the SD card with the corresponding time Mouse Switch to the mouse to make further settings Select and delete Use the option to select a...

Page 11: ...set a distance on the display To open the menu again move the mouse to the left edge of the screen Click on Length and enter the actual length between the two points To complete the calibration click...

Page 12: ...m colour impression Antiflicker Counteracts flickering effects of electric light sources Contrast Sets the difference in the brightness of the light and dark parts of the image Saturation Allows you t...

Page 13: ...e option to format the data media the included micro SD card or a USB pen drive Version 6 2 Menu at the bottom Zoom in Enlarges the image by a factor of 0 1 up to a maximum of 10 Zoom out Reduces the...

Page 14: ...ze Freezes the image Grid options Settings to show or hide scale bars a grid Line options Compare to saved image Opens the file overview shows the selected image on the right side of the screen Quarte...

Page 15: ...tion method Screen switch is off Switch on the display using the display switch 8 Contact If you have any questions suggestions or technical problems please do not hesitate to contact us You will find...

Page 16: ...Pesciatina 878 B Interno 6 Halkal Merkez Mah Ensign Way Southampton 55010 Loc Gragnano Pehlivan Sok No 6 C Hampshire Capannori Lucca 34303 K k ekmece stanbul United Kingdom SO31 4RF Italia T rkiye Tel...

Reviews: