Safety notes 

Please read this manual carefully and completely before you use the device for the first time. The 
device  may  only  be  used  by  qualified  personnel  and  repaired  by  PCE  Instruments  personnel. 
Damage or injuries caused by non-observance of the manual are excluded from our liability and 
not covered by our warranty. 
 

 

The device must only be used as described in this instruction manual. If used otherwise, 
this can cause dangerous situations for the user and damage to the meter. 

 

The instrument may only be used if the environmental conditions (temperature, relative 
humidity, …) are within the ranges stated in the technical specifications. Do not expose 
the device to extreme temperatures, direct sunlight, extreme humidity or moisture. 

 

Do not expose the device to shocks or strong vibrations. 

 

The case should only be opened by qualified PCE Instruments personnel. 

 

Never use the instrument when your hands are wet. 

 

You must not make any technical changes to the device. 

 

The appliance should only be cleaned with a damp cloth. Use only pH-neutral cleaner, 
no abrasives or solvents. 

 

The device must only be used with accessories from PCE Instruments or equivalent. 

 

Before each use, inspect the case for visible damage. If any damage is visible, do not 
use the device. 

 

Do not use the instrument in explosive atmospheres. 

 

The measurement range as stated in the specifications must not be exceeded under 
any circumstances. 

 

Non-observance of the safety notes can cause damage to the device and injuries to 
the user. 

 
We do not assume liability for printing errors or any other mistakes in this manual. 
 
We expressly point to our general guarantee terms which can be found in our general terms of 
business. 
 
 
 

 

Summary of Contents for PCE-HMM

Page 1: ...Meter PCE HMM User Manual User manuals in various languages fran ais italiano espa ol portugu s nederlands t rk polski can be found by using our product search on www pce instruments com Last change...

Page 2: ...lues HOLD function 4 5 5 Averaging 4 5 6 Recall the average value 5 5 7 Delete the totalising memory 5 5 8 Battery voltage display 5 5 9 Switch off the meter 5 6 Factors influencing moisture measureme...

Page 3: ...ure Do not expose the device to shocks or strong vibrations The case should only be opened by qualified PCE Instruments personnel Never use the instrument when your hands are wet You must not make any...

Page 4: ...ng function average value calculation Display light automatic Power off automatic Calibration automatic Power supply 9 V block battery Dimensions 772 x 70 x 48 mm 30 3 x 2 7 x 1 8 in edition with 50 c...

Page 5: ...Make a measurement As soon as the meter is switched on either moisture or temperature values are displayed continuously 2 x per second depending on the set mode The flashing decimal point indicates t...

Page 6: ...ure value is stable This can take several minutes Only read the value when it no longer changes Note that the probe itself heats up through repeated penetration Let the probe cool down accordingly Tem...

Page 7: ...rent display press and release the Moisture key 5 7 Delete the totalising memory To clear the totalising memory switch off the meter and turn it back on manually The totalising memory is not deleted w...

Page 8: ...points for a few days 7 Maintenance and cleaning Before the season and if visibly dirty clean the tip of the meter and the probe with fine steel wool and or alcohol Store the meter in a dry and safe p...

Page 9: ...es Due to the contained pollutants batteries must not be disposed of as household waste They must be given to collection points designed for that purpose In order to comply with the EU directive 2012...

Page 10: ...esciatina 878 B Interno 6 Halkal Merkez Mah Ensign Way Southampton 55010 Loc Gragnano Pehlivan Sok No 6 C Hampshire Capannori Lucca 34303 K k ekmece stanbul United Kingdom SO31 4RF Italia T rkiye Tel...

Reviews: