PCE Instruments PCE-HMM User Manual Download Page 1

 

©  PCE Instruments 

 

 
 
 
 
 

 

 

Hay Moisture Meter PCE-HMM 

User Manual 

User manuals in various languages (français, 

italiano, español, português, nederlands, türk, polski, 

русский, 

中文

) can be found by using our 

product search on: www.pce-instruments.com 

Last change: 13 October 2022 

v1.0 

E

nglis

h

 

Summary of Contents for PCE-HMM

Page 1: ...Meter PCE HMM User Manual User manuals in various languages fran ais italiano espa ol portugu s nederlands t rk polski can be found by using our product search on www pce instruments com Last change...

Page 2: ...lues HOLD function 4 5 5 Averaging 4 5 6 Recall the average value 5 5 7 Delete the totalising memory 5 5 8 Battery voltage display 5 5 9 Switch off the meter 5 6 Factors influencing moisture measureme...

Page 3: ...ure Do not expose the device to shocks or strong vibrations The case should only be opened by qualified PCE Instruments personnel Never use the instrument when your hands are wet You must not make any...

Page 4: ...ng function average value calculation Display light automatic Power off automatic Calibration automatic Power supply 9 V block battery Dimensions 772 x 70 x 48 mm 30 3 x 2 7 x 1 8 in edition with 50 c...

Page 5: ...Make a measurement As soon as the meter is switched on either moisture or temperature values are displayed continuously 2 x per second depending on the set mode The flashing decimal point indicates t...

Page 6: ...ure value is stable This can take several minutes Only read the value when it no longer changes Note that the probe itself heats up through repeated penetration Let the probe cool down accordingly Tem...

Page 7: ...rent display press and release the Moisture key 5 7 Delete the totalising memory To clear the totalising memory switch off the meter and turn it back on manually The totalising memory is not deleted w...

Page 8: ...points for a few days 7 Maintenance and cleaning Before the season and if visibly dirty clean the tip of the meter and the probe with fine steel wool and or alcohol Store the meter in a dry and safe p...

Page 9: ...es Due to the contained pollutants batteries must not be disposed of as household waste They must be given to collection points designed for that purpose In order to comply with the EU directive 2012...

Page 10: ...esciatina 878 B Interno 6 Halkal Merkez Mah Ensign Way Southampton 55010 Loc Gragnano Pehlivan Sok No 6 C Hampshire Capannori Lucca 34303 K k ekmece stanbul United Kingdom SO31 4RF Italia T rkiye Tel...

Reviews: