3  Specification 

3.1  Technical specifications 

Sound level 

Applied Standard 

IEC61672-1 CLASS2 

Accuracy 

±3.0 dB 

Display 

4 Digits 

Resolution 

0.1 dB 

Frequency response 

31.5 Hz … 8 kHz 

Measurement range 

Auto: 35 dB … 130 dB 

Frequency weighting 

dBA 

Microphone 

½ inch electric condenser microphone 

Light 

Measurement range 

0 … 200,000 lux; 0 Fc … 20,000 Fc  

Spectral response 

CIE photoptic (CIE human eye response curve) 

Spectral accuracy 

CIE 

Vλ function f1’

6% 

Cosine response 

f2’

2% 

Accuracy 

±15 % 

Photo detector 

One silicon photo diode with filter 

Air velocity 

Measurement range 

0.5 … 30.0 m/s 

Accuracy 

±10 % 

Measurement units 

m/s, km/h, ft/min, knots, mph 

Temperature 

Measurement range 

-

40 … +70 °C (-40 … +158 °F) 

Accuracy 

±2.0 °C (±3.6 °F) 

Resolution 

0.1 ° 

Measurement units 

°C / °F 

Humidity 

Measurement range 

10 … 90 % RH 

Accuracy 

±5 % RH 

Resolution 

0.1 % 

General specifications 

Data update 

1 time/sec 

Maximum value 

MAX 

Minimum value 

MIN 

Data hold 

HOLD 

Auto power off 

Automatic power-off after approx.. 15 minutes of inactivity  

Power supply 

1 x 9 V battery (006P, NEDA1604 or IEC6F22) 

Battery life 

Approx. 30 hours 

Operating conditions 

-

20 … +60 °C; 10 … 90 % RH 

Storing conditions 

-

40 … +60 °C; 10 … 75 % RH 

Dimensions 

252 x 66 x 33 mm 

Weight 

568 g 

3.2  Accessories

 

1 x PCE-EM 883 
1 x temperature and humidity probe 
1 x anemometer probe 
1 x light detector 
1 x wind screen 
1 x screw driver (for calibration screw) 
1 x 9 V battery 
1 x user’s manual 

Summary of Contents for PCE-EM 883

Page 1: ...ter FL 33458 USA From outside US 1 Tel 561 320 9162 Fax 561 320 9176 info pce americas com www pce instruments com english www pce instruments com PCE Instruments UK Ltd Units 12 13 Southpoint Busines...

Page 2: ...ation 6 5 1 Getting started 6 5 2 Switch between temperature and humidity measurements 6 5 3 Display backlight 6 5 4 Data hold 6 5 5 Select the measuring units 6 5 5 1 Wind speed 6 5 5 2 Light 7 5 6 O...

Page 3: ...epaired by PCE Instruments personnel There is no warranty of damages or injuries caused by non observance of the manual The device may not be used in altitudes of more than 2 000 meters The device may...

Page 4: ...10 Measurement units m s km h ft min knots mph Temperature Measurement range 40 70 C 40 158 F Accuracy 2 0 C 3 6 F Resolution 0 1 Measurement units C F Humidity Measurement range 10 90 RH Accuracy 5 R...

Page 5: ...on 8 Power ON OFF button 9 Funktion button 10 MAX MIN button 11 C F selection button 12 Potentiometer calibration for sound level calibration screw 13 Connection for anemometer and photometer probe 14...

Page 6: ...s about 1 1 5 m If you want to use an external power supply use the connection on the side of the device see 15 in chapter 4 1 5 2 Switch between temperature and humidity measurements To switch betwee...

Page 7: ...nimum value capturing press the MAX MIN button again The display now shows the minimum value as well as a MIN indication To exit the MAX MIN mode just press the MAX MIN button once more 5 9 Select the...

Page 8: ...contact PCE Instruments 6 1 PCE Instruments UK By post PCE Instruments UK Ltd Units 12 13 Southpoint Business Park Ensign Way Southampton Hampshire United Kingdom SO31 4RF By phone 02380 987 035 6 2 P...

Reviews: