5. Operation
5.1 Switching on and off:
- Press the On/Off button (6) to turn on the unit.
- After approx. 20 s without use, the unit switches itself off automatically.
- Press the On/Off button (6) to turn off the unit.
5.2 Measurement
- Apply approx. 1-2 cm of reflective tape to the measuring object that is not yet rotating.
- A bright environment has a negative effect on reflection and the measurement result.
If necessary, shade the area to be measured and avoid direct sunlight.
Sunlight.
- To take a measurement, press the measuring button (2) and point the laser at the
rotating object.
- Watch out! Rotating components are dangerous!
5.3 Hold function
- The instrument automatically switches to the hold function after the measurement.
5.4 Max/Min/Avg measured value
- Press the Max button (8) once to read the maximum value of the measurement.
- Press the Max button (8) twice to read the minimum value.
- Press the Max button (8) three times to read the average value (AVG).
5.5 Turning on the display illumination
- Press the light button (5) to switch on the display illumination.
- Press the light button (5) again to turn off the backlight.
5.6 Auto measurement function
- Press the Auto button (7) to start an automatic measurement. Press
Press the button again to exit Auto mode.
- Note: The laser is permanently active in Auto mode, the trigger key (2) does not have to be pressed.
can be operated.
5.7 Recording function
- In Auto mode, press the REC button (9) to start the measurement recording.
- A maximum of 60 measured values can be stored.
- Press the REC key (9) again to pause the measurement.
5.8 Measuring interval in recording mode
- Press and hold the REC button (9) and turn the meter on to display the
Set the recording interval.
- While holding down the REC button (9), press the backlight button (5) to adjust the recording interval.
Interval time or the Auto button to increase the time.
- The time interval can be set from 1-99 sec.
© PCE Instruments
5.9 Battery
- If the meter does not turn on or the battery indicator is lit, replace the meter.
the 9 V battery as soon as possible.
- To do this, press the arrow symbol of the battery compartment and slide it down.
After inserting a new battery, close the cover again. Note
the correct polarity.