Field of view / distance to spot ratio 

The meter's field of view is 13:1, for example, if the meter is 13 inches from the target spot, the 
diameter of the target must be at least 1 inch. Other distance ratios are shown below in the field 
of view diagram. 
 

 

 

Technical specifications 

Measurement range 

-50 

… 380 

 / -5

8 … 716 

 

-50 

… 580 

 

/ -5

8 … 1076 

 

Resolution 

0.1 

/

 

Accuracy 

-50 

… 0 

 / -58 

… 32 

:

 ±4 

 / 7 

 

Above 0 

: ±2 % from reading or ±2 

 / 3.6 

, whichever 

is greater 

Field of  view  /  distance  to  spot 
ratio 

D:S = approx. 13:1 (D=distance, S=spot) 

Response time 

<1 s 

Emissivity 

Adjustable from 0.1 

… 1.0 

Spectral response 

… 14 µm 

Over-range indication 

“HI” indicates that upper temperature limit is exceeded 
“LO” indicates lower temperature limit is fallen below 

Temperature display 

Auto display, “-” means negative, positive value shown w/o 
sign 

Diode laser 

Output <1mW, 630 

… 670nm, class 2 

Automatic Power Off 

Meter shuts off automatically after 15 seconds of inactivity 

Operating temperature 

… 50 

 / 32 

… 122 

 

Storage temperature 

-20 

… 60 

 / -4 

… 158 

 

Operating humidity 

10 

… 95 % RH 

Storage humidity 

<80 % RH 

Power supply 

9 V battery 

Weight 

121 g 

Dimensions (H x W x D) 

144.6 x 75.0 x 38.5 mm 

 

 

Summary of Contents for PCE-660

Page 1: ...ermometer PCE 660 User Manual User manuals in various languages fran ais italiano espa ol portugu s nederlands t rk polski can be found by using our product search on www pce instruments com Last chan...

Page 2: ...tions 2 5 Device description 3 6 Delivery contents 3 7 Operation 3 7 1 How to make a measurement 3 7 2 Settings 4 7 3 Battery replacement 4 8 Further information 5 8 1 Field of view 5 8 2 Distance and...

Page 3: ...ned with a damp cloth Use only pH neutral cleaner no abrasives solvents or volatile liquids The device must only be used with accessories from PCE Instruments or equivalent Before each use inspect the...

Page 4: ...e to spot ratio D S approx 13 1 D distance S spot Response time 1 s Emissivity Adjustable from 0 1 1 0 Spectral response 8 14 m Over range indication HI indicates that upper temperature limit is excee...

Page 5: ...How to make a measurement Hold the meter by its handle grip and point it towards the surface to be measured Pull and hold the trigger button to turn on the meter The SCAN icon will appear and the meas...

Page 6: ...he laser backlight key to decrease the emissivity value In measurement mode press the unit key to switch the temperature unit from to or vice versa To power on or disable the laser pointer press the l...

Page 7: ...l the hot spot is located 8 4 Tips Not recommend for measuring shiny or polished metal surfaces like stainless steel aluminium etc You cannot make measurements through transparent surfaces such as gla...

Page 8: ...d pollutants batteries must not be disposed of as household waste They must be given to collection points designed for that purpose In order to comply with the EU directive 2012 19 EU we take our devi...

Page 9: ...975 114 Fax 1 561 320 9176 Fax 44 0 2380 98703 9 Fax 39 0583 974 824 info pce americas com info industrial needs com info pce italia it www pce instruments com us www pce instruments com english www...

Reviews: