background image

 
 
 

[email protected]

 

 

 

3

1.  Introduction                                                  

PCE-2000 is an advanced Hand-held hardness tester, characterized by its high accuracy, wide measuring 
range and simplicity for operation. It is suitable for testing hardness of the ordinary metal and widely applied in 
many industrial fields, such as petroleum, chemistry machinery and electric power industries etc. 

 

2. Typical Applications                                           



 Installed machines and permanent parts of assembled system 



 Molding surface of die 



 Heavy work-pieces 



 Ineffectiveness analysis of pressure-vessel, turbo-generator set etc. 



 Bearing and other messy produced parts at production line 



 Obtaining test data requested as original formal records 



 Identifying metallic material stored in a warehouse 

 

3.  Technical Data   

 

                                            

Display : 128×64 LCD 
Display error: 

±

0.5   

Relative repetitive display error: 

±

0.8   

Memory: 1250 

      Battery:  2 pieces AAA batters with working more than 48 hours continuously ( no backlight) 

Auto-off: 2 minutes without working 
Size:    108×62×25 mm 

      Weight: 180g 

 

4.  Function of Keyboard                                          

n

 

 ON/OFF             

o

 

 Move/Print data   

p

 

 Move/Backlight       

q

  

Delete 

r

 

 Re-read              

s

  

Menu/Enter 

5.  Function of Display

    

                                       

n

 hardness scale 

o

 symbol of average 

p

 average value 

q

 measuring value 

r

 direction and materials 

s

 type of impact device 

t

 times of measurement/average 

u

 memory location 

v

 date and time 

w

 battery power 

 

Summary of Contents for PCE-2000

Page 1: ...ical Services Ltd Unit N12B Tursdale Business Park Co Durham DH6 5PG United Kingdom Phone 44 0 191 377 3398 Fax 44 0 191 377 3357 info tursdaletechnicalservices co uk http www industrial needs com Man...

Page 2: ...ace 4 6 2 Support to test samples 4 6 3 Advice 4 6 4 Test sample should not be magnetic in property 4 7 Operation of the Instrument 4 7 1 Starting 4 7 2 Function of Menu 4 7 2 1 Measurement 5 7 2 2 Im...

Page 3: ...etc Bearing and other messy produced parts at production line Obtaining test data requested as original formal records Identifying metallic material stored in a warehouse 3 Technical Data Display 128...

Page 4: ...than 0 8mm 6 3 Advice When the test sample is a large plate long bar or bent work piece impact force can cause it deformed or unstable and bring about error in measurement even if its weight or thick...

Page 5: ...surement and material 1 D 2 DC 3 D 15 4 DL 5 C 6 G 7 E Press key or key to select the type of impact device Press key to confirm 7 2 3 Direction You can select 5 directions such as 1 2 3 4 5 Press key...

Page 6: ...o confirm 7 2 8 Date and Time The gauge provides real display of date and time Through pressing key or key you can change or modify the date and time 7 2 9 Location The gauge provides 1250 memory loca...

Page 7: ...iron GGG 400 660 131 367 Cast aluminum 174 560 20 190 Brass 200 550 13 5 95 3 40 173 Bronze 300 700 60 290 Copper 200 690 45 315 No Materials D DC D 15 C E G DL 1 Steel 2 Tool steel 3 Stainless steel...