background image

 

 

©  PCE Instruments 

 

6.5 

Max/Min mode  

1. 

Press the MAX (PCE-LMD 5) or MAX/MIN (PCE-LMD 10) key once. The "MAX" icon 
will appear on the LCD and the maximum value will be displayed on the LCD until a 
higher value is measured. 

2. 

Press the MIN (PCE-LMD 5) or MAX/MIN (PCE-LMD 10) key again. The "MIN" icon will 
appear on the LCD and the minimum value will be displayed on the LCD until a lower 
value is measured. 

3. 

Press the MAX/MIN key again. The MAX MIN icon will flash on the LCD and the real-
time value will be displayed. Now the MAX and MIN values are recorded.  

4. 

Press the MAX/MIN key again. This will take you back to step 1. 

5. 

To  exit  the  MAX-MIN  mode,  press  and  hold  the  MAX/MIN  key  for  approximately  2 
seconds until the "MAXMIN" icon disappears from the LCD.   

6.6 

Hold data 

Press  the  "HOLD"  key.  The  digital  reading  is  held  and  the  "HOLD"  icon  appears  on  the  LCD. 
Press the "HOLD" key again to return to normal operation.  
 

Note

When  the  Data  Hold  function  is  activated,  the  analogue  bar  graph  above  the  measured  value 
changes according to the current light intensity.  

6.7 

Hold a PEAK value 

The peak hold function allows the lux meter to detect the light pulse rising or falling to 10 µs.  
 

1. 

Press the PEAK key. The "Pmax" icon will appear on the LCD. The lux meter measures 
the MAX light pulse and displays the MAX value. The data will be updated until a higher 
value is detected. 

 

2. 

Press the PEAK key again. The "Pmin" icon will appear on the LCD. The lux meter will 
display  the  MIN  light  pulse  value.  The  data  will  be  updated  until  a  lower  value  is 
detected.  

 

3. 

To exit the Peak Hold function, press the PEAK key for approximately 2 seconds until 
the "Pmax" or "Pmin" icon disappears from the LCD.  

 

 

Summary of Contents for LMD 10

Page 1: ...LMD 10 Lux Meter User Manual User manuals in various languages fran ais italiano espa ol portugu s nederlands t rk polski can be found by using our product search on www pce instruments com Last chang...

Page 2: ...perating instructions 4 6 1 Sensor 4 6 2 Switch on off the meter 4 6 3 Select units 4 6 4 Measurement 4 6 5 Max Min mode 5 6 6 Hold data 5 6 7 Hold a PEAK value 5 6 8 Relative value 6 6 9 Backlight 6...

Page 3: ...ument when your hands are wet You must not make any technical changes to the device The appliance should only be cleaned with a damp cloth Use only pH neutral cleaner no abrasives or solvents The devi...

Page 4: ...spectral filter Peak Hold Detection of the peak light intensity of the shortest 10 S Battery level indicator flashes when the battery voltage is too low Data logger PCE LMD 10 32 000 sets of measured...

Page 5: ...N key PCE LMD 5 MIN MAX key PCE LMD 10 10 MAX key PCE LMD 5 REC key PCE LMD 10 only 11 Light sensor Notice The micro USB socket is located at the bottom of the meter 5 2 Display 1 MAX MIN value 2 Rela...

Page 6: ...in use 6 2 Switch on off the meter Press and release the key to turn on the light meter and press and hold the same key for 3 seconds to turn off the light meter 6 3 Select units Press the key to sel...

Page 7: ...rs from the LCD 6 6 Hold data Press the HOLD key The digital reading is held and the HOLD icon appears on the LCD Press the HOLD key again to return to normal operation Note When the Data Hold functio...

Page 8: ...starting the recording function connect the light meter to the PC via Micro USB and set up the parameters via the Smart Logger software Set the start mode to by key and disconnect the light meter fro...

Page 9: ...flashes Use the DC 5V power adaptor to connect to the micro USB charging port on the bottom of the meter The battery icon on the LCD will indicate that the battery is charging and will disappear when...

Page 10: ...Unit 11 Southpoint Business Park Via Pesciatina 878 B Interno 6 Halkal Merkez Mah Ensign Way Southampton 55010 Loc Gragnano Pehlivan Sok No 6 C Hampshire Capannori Lucca 34303 K k ekmece stanbul Unite...

Reviews: