Manual
3
1
Introduction
Thank you for purchasing an Ignition Cable Tester ADD760 from PCE Instruments.
The Ignition Cable Tester ADD760 is a device for non-destructive measurement of motor voltage.
Therefore the sensor of the device has to be connected to a cable, which leads to a cylinder. With
the engine running you can check if the correct voltage applies for explosions in the engine. As a
vital device for control measurements, e. g. in production, quality assurance or at repair shops, the
Ignition Cable Tester ADD760 is part of the engineer
’s basic equipment. It is ideally suited for
detecting damages due to an accident for instance. But the Ignition Cable Tester ADD760 is also
suitable for industrial use, e. g. for incoming and dispatch control. The ergonomically shaped Ignition
Cable Tester ADD760 with integrated sensor and convenient handling is ideal for obtaining
measuring results very quickly.
Benefits:
-
Measures the ignition voltage
-
Indicates the polarity
-
Ignition cables easy to reach due to probe
-
Measuring and testing mode
-
Clearly readable display
-
Simple to handle
-
Quick results
Delivery content:
-
Ignition Cable Tester ADD760
-
Batteries
-
Manual
-
Probe extension
-
Signal receiver
2
Safety notes
-
Please read the manual carefully and completely before using it for the first time. There is no
warranty of damages or injuries caused by non-observance of the manual.
-
If the device isn’t in use for a long period, please remove the batteries.
-
The device must be used in the described way. Using the device otherwise can result in
dangerous situations.
-
The device must not be exposed to extreme temperatures, to direct sunlight, extreme humidity or
wetness.
-
Never use the device with wet hands.
-
You must not make technical changes on the device.
-
The appliance should only be cleaned with a damp cloth. Only use pH-neutral cleaner.
-
The device only has to be used with accessories offered by PCE Instruments or equivalent
replacements.
-
Don’t use the device if the environmental conditions (temperature, humidity,…) are not within the
limits that are given in the specification.
-
The device must not be used in an explosive atmosphere.
If you have any questions please contact PCE Instruments.
3
Device description
Ignition Signal Receiver
It is connected to the ignition cable.
Probe Extension
It extends the distance between sensor and
handheld unit.
Power Button
It switches the device on or off.
Red LED
It shows that a spark exists.
Display
It shows the measured value.
Red and Green LED
It shows the DIS polarity.