PCE Health and Fitness VOC 1 User Manual Download Page 6

 

 

 

©  PCE Instruments 

 

Specifications 

HCHO

 

0.00... 5.00 ppm or mg/m³ 

Resolution 

0.01 ppm or mg/m³ 

Accuracy 

± 5% of measured value 

Measuring range 

 

 

TVOC

 

0.00... 9.99 ppm or mg/m³ 

Resolution 

0.01 ppm or mg/m³ 

Accuracy 

± 5% of measured value 

Response time 

< 2 seconds 

Operating temperature 

32... 104 °F / 0... 40 °C 

Storage temperature 

14... 140 °F / -10... 60 °C  

Power supply 

7.4 V / 1200 mAh LiPo battery 

Power adapter/charger 

9 V / 1 A 

Charging time 

Approx. 2 hours 

Weight 

Approx. 1.3 lbs / 584 g 

Dimensions 

6.5 x 2.4 x 1.0 in / 165 x 60 x 25 mm  

 

On / Off 

Press the ON/OFF key to switch on the meter. 
The battery icon shows the battery level. Depending on the battery level, charge the battery or 
connect the meter to the power supply. 
To switch off the meter, press and hold the ON/OFF key for 3 seconds. 

Auto power off 

The meter enters sleep mode after 30 minutes of inactivity to save energy. 

Operation 

When the meter is switched on, it shows the HCHO value. In the lower part of the display, you 
can see the TVOC reading. The meter required a warm-up phase of up to 90 seconds to show 
stable readings. 

10  Alarm 

Press 

and hold the Down / set key for

 3 seconds. You can now set the lower alarm limit using the 

arrow keys and confirm with the ON/OFF key. The upper alarm limit can then be set in the same 
way.

 

 

11  Set / Unit keys 

With the Up / unit key, you can switch between the measuring units. With the Down / set key, you 
can activate or deactivate the alarm function. 
 

 

Summary of Contents for VOC 1

Page 1: ...r Quality Meter User Manual User manuals in various languages fran ais italiano espa ol portugu s nederlands t rk polski can be found by using our product search on www pce instruments com Last change...

Page 2: ...Contents 1 Safety notes 1 2 Introduction 2 3 Features 2 4 Front Panel Description 2 5 Display 3 6 Specifications 4 7 On Off 4 8 Auto power off 4 9 Operation 4 10 Alarm 4 11 Set Unit keys 4 12 Warranty...

Page 3: ...s The case should only be opened by qualified PCE Instruments personnel Never use the instrument when your hands are wet You must not make any technical changes to the device The appliance should only...

Page 4: ...etc 3 Features Measures total volatile organic compound TVOC and formaldehyde HCHO levels Displays units in parts per million ppm or milligrams per cubic meter mg m Long lasting rechargeable lithium p...

Page 5: ...y 1 Lower alarm level low 2 Upper alarm level high 3 Battery indication 4 Alarm on off 5 Auto Power Off indication 6 HCHO 7 HCHO unit 8 TVOC 9 TVOC unit 10 TVOC reading 11 HCHO reading 12 Air pollutio...

Page 6: ...n the battery level charge the battery or connect the meter to the power supply To switch off the meter press and hold the ON OFF key for 3 seconds 8 Auto power off The meter enters sleep mode after 3...

Page 7: ...d pollutants batteries must not be disposed of as household waste They must be given to collection points designed for that purpose In order to comply with the EU directive 2012 19 EU we take our devi...

Page 8: ...975 114 Fax 1 561 320 9176 Fax 44 0 2380 98703 9 Fax 39 0583 974 824 info pce americas com info industrial needs com info pce italia it www pce instruments com us www pce instruments com english www...

Reviews: