PCE Health and Fitness PCE-RT 11 Instruction Manual Download Page 16

PCE Instruments contact information 

Germany 

PCE Deutschland GmbH 
Im Langel 4 
D-59872 Meschede
Deutschland
Tel.: +49 (0) 2903 976 99 0
Fax: +49 (0) 2903 976 99 29
[email protected]
www.pce-instruments.com/deutsch

United States of America 

PCE Americas Inc. 
711 Commerce Way Suite 8 
Jupiter / Palm Beach 
33458 FL 
USA 
Tel: +1 (561) 320-9162 
Fax: +1 (561) 320-9176 
[email protected] 
www.pce-instruments.com/us 

The Netherlands 

PCE Brookhuis B.V. 
Institutenweg 15 
7521 PH Enschede 
Nederland 
Telefoon: +31 (0)53 737 01 92 
Fax: +31 (0) 53 - 430 36 46 
[email protected] 
www.pce-instruments.com/dutch 

China 

PCE (Beijing) Technology Co.,Ltd 
1519 Room, 6 Building 
Men Tou Gou Xin Cheng, 
Men Tou Gou District 
102300 Beijing 
China 
Tel: +86 (10) 8893 9660 
[email protected] 
www.pce-instruments.cn 

France 

PCE Instruments France EURL 
23, rue de Strasbourg 
67250 SOULTZ-SOUS-FORETS 
France 
Téléphone: +33 (0) 972 3537 17 
Numéro de fax: +33 (0) 972 3537 18 
[email protected] 
www.pce-instruments.com/french 

United Kingdom 

PCE Instruments UK Ltd 
Unit 11 Southpoint Business Park 
Ensign Way, Southampton 
Hampshire 
United Kingdom, SO31 4RF 
Tel: +44 (0) 2380 98703 0 
Fax: +44 (0) 2380 98703 9 
info@

pce-instruments.co.uk

 

www.pce-instruments.com/english 

Chile 

PCE Instruments Chile S.A. 
RUT: 76.154.057-2 
Santos Dumont 738, local 4 
Comuna de Recoleta, Santiago, Chile 
Tel. : +56 2 24053238 
Fax: +56 2 2873 3777 
[email protected] 

www.pce-instruments.com/chile 

Turkey 

PCE Teknik Cihazları Ltd.Şti. 
Halkalı Merkez Mah.

 

Pehlivan Sok. No.6/C 
34303 Küçükçekmece - 

İstanbul 

Türkiye 
Tel: 0212 471 11 47 
Faks: 0212 705 53 93 
[email protected] 
www.pce-instruments.com/turkish 

Spain 

PCE Ibérica S.L. 
Calle Mayor, 53 
02500 Tobarra (Albacete) 
España 
Tel. : +34 967 543 548 
Fax: +34 967 543 542 
[email protected] 
www.pce-instruments.com/espanol 

Italy 

PCE Italia s.r.l. 
Via Pesciatina 878 / B-Interno 6 
55010 LOC. GRAGNANO 
CAPANNORI (LUCCA) 
Italia 
Telefono: +39 0583 975 114 
Fax: +39 0583 974 824 
[email protected] 
www.pce-instruments.com/italiano 

Hong Kong 

PCE Instruments HK Ltd. 
Unit J, 21/F., COS Centre 
56 Tsun Yip Street 
Kwun  Tong 
Kowloon, Hong Kong 
Tel: +852-301-84912 
[email protected] 
www.pce-instruments.cn 

15 

Summary of Contents for PCE-RT 11

Page 1: ...PCE RT 11 Surface RoughnessTester Instruction Manual...

Page 2: ...rational Measure 6 5 1 Measurement preparation 6 5 2 Switch on Switch off 7 5 3 Selecting Parameter 7 5 4 Measuring 8 5 5 Calibration 9 5 6 Battery Recharge 10 6 Daily Maintenance 10 6 1 Maintenance 1...

Page 3: ...using design is durable and helps eliminate electromagnetic interference By using high speed DSP processors for the data processing and calculation measuring and calculation speed is greatly improved...

Page 4: ...ad has a protection door which protects the head of the sensor effectively further guaranteeing the accuracy of measurement 2 Work Principle When the pickup it triggered it is making a linear uniform...

Page 5: ...4 Technical Parameters Roughness Parameters m Ra Rz Rq Rt Stroke Length mm 6 Sampling Length mm 0 25 0 80 2 50 Evaluation Length mm 1 25 4 0 Measurement Range m Ra Rq 0 05 10 0 Rz Rt 0 1 50 Accuracy 1...

Page 6: ...ic force measurement and its rate Touch needle static force measurement 0 016N Force measurement rate 800N m Sensor guide head pressure 0 5N Battery 3 7V Lithium Ion battery Contour Dimension 106 mm 7...

Page 7: ...eparation Remove instrument right now the sensors head door should be closed see illustration below Move to the right to trigger measuring head door switch Open the sensors head protection door to exp...

Page 8: ...re the shutdown of the meter Depress on off button a second time to shutdown In 3 minutes of inactivity the instrument will be turned off 5 3 Selecting Parameter Before measuring the user should set u...

Page 9: ...fter the Testing has disappeared two audio indications will sound indicating the measurement has being finished and the screen will show the measured value Note 1 During the pickup s travel do your be...

Page 10: ...tton Release the start button The tester will enter the status of Calibration as shown below Press the Up Key and Down Key to adjust thedisplaying value to the value 3 14 Put the instrument in the scr...

Page 11: ...5 6 Battery Recharge Plug the charger into the tester s recharge socket and have the tester recharged together with the battery symbol lighting if no lighting plug it again 3 hours recharging time is...

Page 12: ...ches that may make the calibration inaccurate 6 2 Repair If any trouble occurs user should not try to dismantle and repair it The device should be returned to the manufacturer for checking and repair...

Page 13: ...le is arithmetic mean value of the deviation of the profile within sampling length Rz The maximum Height of Irregularities is the distance between maximum depth of the profile peaks and maximum depth...

Page 14: ...Rt is the sum of the height of the highest peak and the depth of the deepest valley over the evaluation length 1 n 1 2 2 Rq n yi i 1 13...

Page 15: ...ny rules If the user disassemble this company product or practices improper safekeeping of transportation or use of products according to the instruction for use correct operation damaged products thi...

Page 16: ...United Kingdom PCE Instruments UK Ltd Unit 11 Southpoint Business Park Ensign Way Southampton Hampshire United Kingdom SO31 4RF Tel 44 0 2380 98703 0 Fax 44 0 2380 98703 9 info pce instruments co uk...

Reviews: