PCE Health and Fitness PCE-PA6000 Operation Manual Download Page 1

POWER

ANALYZER

PCE-PA6000

Your purchase of this POWER ANALYZER marks a step forward

for  you  into  the  field  of  precision  measurement.  Although  this

POWER  ANALYZER  is  a  complex  and  delicate  instrument,  its

durable  structure  developed.  Please  read  the  following

instructions carefully and always keep this manual within easy

reach.

       OPERATION MANUAL

PCE Americas Inc.

711 Commerce Way 

Suite 8 

Jupiter

FL-33458

USA

From outside US: +1

Tel: (561) 320-9162

Fax: (561) 320-9176

[email protected]

www.pce-instruments.com/english

www.pce-instruments.com

PCE Instruments UK Ltd.

Unit 11 

Southpoint Business Park 

Ensign way

Hampshire / Southampton

United Kingdom, SO31 4RF

From outside UK: +44

Tel: (0) 2380 98703 0

Fax: (0) 2380 98703 9

 [email protected]

Summary of Contents for PCE-PA6000

Page 1: ...ns carefully and always keep this manual within easy reach OPERATION MANUAL PCE Americas Inc 711 Commerce Way Suite 8 Jupiter FL 33458 USA From outside US 1 Tel 561 320 9162 Fax 561 320 9176 info pce...

Page 2: ...Do not apply the overload voltage current to the input terminal Remove test leads before open the battery cover Cleaning Only use the dry cloth to clean the plastic case Environment Conditions Install...

Page 3: ...Hz Measurement 12 5 3 AC Watt Hour Whr Measurement 13 5 4 AC Voltage Current Measurement 13 5 5 DC Voltage Current Measurement 14 5 6 Ohm Measurement 15 5 7 AC Watt VA Whr measurement current input co...

Page 4: ...irect input inductive clamp probe or CT current transformer Auto range Built in peak hold data hold function Watt VA measurement with Hi low alarm setting capability RS 232 output interface Exclusive...

Page 5: ...ndication Data Output RS232 serial interface Sampling Time W VA ACA ACV COS Hz Approx 1 5 Sec DCV DCA OHM Approx 1 Sec Operating Temp 0 to 50 32 to 122 Operating Less than 80 R H Humidity Power Supply...

Page 6: ...tor 0 5 ACA ACV frequency response is from 40 to 400 Hz Max volt current input signal value Volt input Max AC 600V Current input Max AC 10A Watt AC true power current input cooperate with inductive pr...

Page 7: ...d 220V 15 c ACA ACV input signal is sine wave 50 60 Hz ACA ACV frequency response is from 40 to 400 Hz POWER FACTOR current mode from direct input only Range Resolution Accuracy 0 01 to 1 00 0 01 1 5...

Page 8: ...CURRENT current mode from direct input Range Resolution Accuracy ACA 0 05 A to 1 999 A 1 mA 1 3d 2 00 A to 10 00 A 10 mA DCA 0 01A to 10 00 A 10 mA 1 1d Max input current AC 10 A DC 10 A ACA accuracy...

Page 9: ...001 Whr to 9 999 Whr 0 001 Whr 10 00 Whr to 99 99 Whr 0 01 Whr 100 0 Whr to 999 9 Whr 0 1 Whr 1000 Whr to 9999 Whr 1 Whr 10 K Whr to 99 99 K Whr 10 Whr 100 K Whr to 999 9 K Whr 100 Whr 1000 K Whr to 9...

Page 10: ...9 9 Hz 0 1 Hz 1 1d 100 Hz to 999 Hz 1 Hz Auto range Frequency signal input voltage level should 6V 600 V Remark The above specifications are tested under the environment RF Field Strength less than 3...

Page 11: ...3 FRONT PANEL DESCRIPTION Fig 1 8...

Page 12: ...or Hz Button 3 10 Peak Hold Button 3 11 Data Hold Button 3 12 Current Mode Button 3 13 Button Alarm Set 3 14 Button Alarm Set 3 15 Alarm Set Button 3 16 Watt Terminal 3 17 V Ohm Terminal 3 18 COM Term...

Page 13: ...st leads from the circuit under test while changing the measurement function 5 Operate the instrument only in the ambient temperature range of 0 to 50 32 to 122 and less than 80 Relative humidity 6 Do...

Page 14: ...Current In Switch 3 6 Fig 1 to the DIRECT position 4 Power off the Power Source of the measured installation Make the wire connection and connect the test leads into terminals 3 16 3 17 3 18 3 19 as...

Page 15: ...0A Line frequency Hz measurement 8 During the Watt measurement push the PF Hz Button 3 9 Fig 1 once will show Line frequency value instead of the PF value Push the PF Hz Button again the Hz value will...

Page 16: ...new measurement again 5 4 AC Voltage AC Current Measurement 1 Push the Power switch 3 2 Fig 1 to On position On 1 Off 0 2 Select the AC V A WATT Switch 3 3 Fig 1 3 Select the Current In Select Switch...

Page 17: ...nto circuit under test c The display will show the DC voltage directly Remark When the DC mark on the LCD be flashed it means the measured display value is negative DC voltage 5 DC Current measurement...

Page 18: ...circuit resistance under test 6 Read resistance value on digital display 5 7 AC Watt VA Whr measurement current input cooperate with CT current transformer Other measurement procedures are same as th...

Page 19: ...res are same as the 5 1 5 2 except 1 Wire connection ref Fig 4 Voltage V Terminal 3 17 Fig 4 COM terminal 3 18 Fig 4 Current The output plug of the inductive current probe 1 ACmV per 1 ACA such as PCE...

Page 20: ...LCD will show the HOLD marker Push the Data Hold Button again will release the DATA HOLD function Data hold function is not available for ohm range 5 10 Peak Hold During the measurement Push the Peak...

Page 21: ...Max Min marker when adjust the Alarm Set Button 3 Button 3 13 Fig 1 is used to select the digit 4 Button 3 14 Fig 1 is used to select the value 0 1 2 9 of each digit 5 The buzzer will alarm when the...

Page 22: ...measurement may still be made for several hours after appear low battery indicator 2 Loose the screw slide the Battery Cover 3 23 Fig 1 away from the instrument and remove the batteries 3 Replace the...

Page 23: ...ter PC 3 5 mm jack plug 9W D Connector Center Pin Pin 4 3 5 mm jack plug Ground shield Pin 2 2 2 K resistor Pin 5 The 16 digit data stream will be displayed in the following format D15 D14 D13 D12 D11...

Page 24: ...8 ACV 50 ACA 52 Minute 62 KVA 64 W hr F2 COS PF 54 D13 1 Top left display 2 Top right display 3 Bottom left display 4 Bottom right display to show display 1 2 LCD position DISPLAY 3 4 D14 4 D15 Start...