background image

 

 

©  PCE Instruments 

 

5.2 

Set flash frequency 

5.2.1 

Quick adjustment 

Use the X 2 and ÷2 keys to quickly change the flash frequency. 
"X 2" doubles the currently set flash frequency. 
Example based on flash frequency 100/min: 
100 

 X 2 

 200 

 X 2 

 400 

"÷2 " halves the currently set flash frequency. 
Example based on flash frequency 400/min: 
400 

 ÷ 2 

 200 

 ÷ 2 

 100 

5.2.2 

Moderate adjustment 

Use the + / - rotary switch at the rear side for moderate flash frequency adjustment. 
Turning  to  the  right  increases  the  flash  frequency  and  turning  to  the  left  decreases  the  flash 
frequency. 
When turning slowly, only  the last digit of the flash frequency is changed. When turning faster, 
the tens or hundreds of the flash frequency are changed. 

5.2.3 

Fine-tuning 

Use the "+" and "-" keys for fine adjustment. 
Per keystroke, the last digit of the flash frequency is changed by the value 1. 
Holding the key changes the tens or hundreds of the flash frequency.

 

5.3 

Rotational speed measurement  

 

Place a unique mark on the object to be measured and switch on the machine. 

 

Switch on the stroboscope via the switch on the back. 

 

Use the "Int / Ext Signal" key to select the Internal option. 

 

Aim the light cone at the object to be measured. 

 

Set a flash frequency that is above the expected speed of the object to be measured. 

 

Change the flash frequency as described in chapter 5.2 until the mark shows a single 
standing image. If 2, 3 or more standing marks are visible, reduce the flash frequency 
until only one standing mark is visible. 

 

To check, double the flash frequency with the "X 2" key. Now you should see 2 
opposite markings. Double the flash frequency again with the "X 2" key. Now you 
should see 4 standing marks in a cross arrangement. 

 

 

Summary of Contents for PCE-DSX 20

Page 1: ...Stroboscope User Manual User manuals in various languages fran ais italiano espa ol portugu s nederlands t rk polski can be found by using our product search on www pce instruments com Last change 19...

Page 2: ...Front and back 3 4 2 Top and bottom 4 5 Operation 4 5 1 Preparation 4 5 2 Set flash frequency 5 5 3 Rotational speed measurement 5 5 4 External input 6 5 5 Synchronised output trigger output 7 5 6 Mo...

Page 3: ...yes Do not point the stroboscope at other people Light pulses of more than 5 Hz may cause people with photosensitive epilepsy to suffer a seizure Do not touch the lamp with bare hands The case should...

Page 4: ...PM 0 1 of rdg 2 dgt 9999 RPM 1 RPM 35000 RPM 10 RPM Level ext trigger High 2 5 12 V Low 0 8 V Lamp type Xenon flash Flash response time 10 30 s Colour temperature 6500 K Flash output 8 joules Beam ang...

Page 5: ...description 4 1 Front and back Screws protective glass Ext trigger input signal output Xenon flash lamp 230 V AC input Internal external selection key MODE key Key X 2 doubling Key Key 2 halving Key...

Page 6: ...ED Trigger mode LED mSec mode LED Tripod thread 5 Operation 5 1 Preparation Before first use remove the film from the front protective glass and the display Connect the stroboscope to the power supply...

Page 7: ...s for fine adjustment Per keystroke the last digit of the flash frequency is changed by the value 1 Holding the key changes the tens or hundreds of the flash frequency 5 3 Rotational speed measurement...

Page 8: ...cope is signalled by flashing of the display and the flash triggering is set 5 4 1 Rotational speed Select speed with the MODE key As soon as an external signal is present the stroboscope flashes in t...

Page 9: ...e maximum time of use of the stroboscope per measurement should not exceed the following times The pause between measurements should be at least 10 minutes Flash frequency Duration 2000 RPM 4 hours 20...

Page 10: ...pollutants batteries must not be disposed of as household waste They must be given to collection points designed for that purpose In order to comply with the EU directive 2012 19 EU we take our devic...

Page 11: ...Unit 11 Southpoint Business Park Via Pesciatina 878 B Interno 6 Halkal Merkez Mah Ensign Way Southampton 55010 Loc Gragnano Pehlivan Sok No 6 C Hampshire Capannori Lucca 34303 K k ekmece stanbul Unite...

Reviews: