2. SPECIFICATIONS 

1)   Indication: 3112 digit LCD with Maximun indication 
 value 

1999. 

2)   Overload indication: Indicated by "OL" at the highest 
 

position on the left lateral side. 

3)   Low battery indication: when"~"is indicated by the LCD 
 

indicator, lt means that the battery should be renewed.  

4)   Battery life: Approximately 200 hours.  
5)   Operation temperature/humidity: 0

°

C ~40

°

C, Below 

 80% 

RH. 

6)   Length of wiring for light receiver: Approximately 1.5 m.  
7)   Power supply: 006P DC 9V.  
8) 

Dimension and weight of meter: 

 

Dimension: 200x98x40mm. Weight:325g  

9)   Dimension and weight of light receiver: 
 

Dimension: 66x125mm. Weight:110g. 

10)   Accessory: One operation manual, one light receiver 
 

cover, one carrymg case and one battery.  

11)   Specifications 
 (Rectification 

should 

be made based on the standard 

 

af color temperature 2856°K) 

12)   Sampling rate: 2.5 times persecond.

 

Peak Wavelength (nm): 560 

• 

Silicon Diode light receiving wave is found to long and 
extensive in area.  

• 

Testing: Lux and Fc are available for selection.  

• 

Ranges for Lux: 200, 2000, 20000, 50000 Lux. 

        Fc: 20, 200, 2000, 5000 Fc.  

• 

Testing Range: Lux from 0.1 --100000 Lux. 

        Fc from 0.01 -.10000 Fc. 

• 

With DATE HOLD function which allows testing indication 
value to be fixed at will. 

• 

Large size LCD indication, featured for low battery 
indication function. 

• 

MAX function: Hold the maximun value on the LCD 
indication. 

• 

RANGE funtion: range touch selector. 

• 

LuxlFc function: For selsction of Lux or Fc. 

• 

POWER Function:For power on and off. 

• 

CLASS: Conforms to JIS C 1609 - 1993 general  
A dass. 

• 

Spectral Response 

3. OPERATION PROCEDURE 

1) Open the carrying case. 
2) Turn on the Power Switch. Choose the unit of 
Lux of Fc which you want to test. Then choose the 
right range appropriate for testing. 
3) Remove the cover of the light receiver, Put the 
light receiver at the spot where the testing of source 
of light i

s

 to be conducted, Auto testing will then be 

conducted by the meter, Read the testing value 
after the reading indicated becomes stable. 
4) when "OL" is shown at the highest position at the 
left lateral side, overload 

is 

indicated, Then please 

choose another range which is located at a 
comparatively higher position. Attention: when 
testing 

is 

fixed at the range of 

20000Lux,50000Lux,5000Fc,the numencal value 
shown by the indicator must be multiplied by 10 
times or 100 times to get the true value tested. 
5) If you want to keep the reading value on the LCD 
permanently after testing, press the D-H Key 
whereby the reading value will be locked 
permanently up. Press the D-H Key once again 
when you want to remove the previous locking. 
6) After testing, put the cover of the light receiver 
back to its former position, and turn off the switch. 
7)After testing is completed, the indication value 
should be 000 no matter 
what its range would be after putting the cover of the 
light receiver back to its former position. Please 
adjust 0 ADJ to enable LCD to indicate 000 if zero 
cannot be recover. If zero still can not be 
recovered, lt means that the meter breaks down. 
 

5. ATTENTION 

1)In the measurement of illumination, the reading will 
be caused to jump by the variance of power or the 
shadow of surrounding people. The condition of the 
surrounding temperature, air current and ventilation 
will also cause the source of light to vary. 
2)When the source of light 

is 

received too early by 

the light receiver, the precision of the mefer will be 
reduced. Always keep the cover of the light receiver 

in 

its place. Avoid to allow the light receiver to be 

come overloaded or avoid to mput high source of 
light when testing is being conducted at low 
illumination. 
3)The mark set for referencing the testing of source 
of light is located at the right top end of the light 
recieving ball plane. 
4)When the meter is turned on and the light receiver 
cover is put in its place, 000 should be indicated by 
LCD, However, if the voltage of the battery varied 
and the low battery sign"ö" is still not yet indicated 
it, will easily prevent zero from being recovered 
when the meter is being switched on 0 ADJ should 
then be adjusted to turn lt back to zero be fore 
measurement should be started. 
5)When low battery sign"~"is indicated, the 
batteries should be renewed.lf zero cannot be 
recovered after the battery has been renewed, 
Please adjust 0 Addition so as recover zero. 
6)When the meter is not in use, please keep the 
cover of the light receiver in its place to avoid the 
sensor from wearing out. 
7)When it is not in use for a bong time, please take 
the batteries away. And avoid to keep lt in a place of 
high temperature and humidity.  

ATTACHED BELOW IS A STANDARD 
REFERENCE TABLE OF ILLUMINATION

 

 